Hot Water Inlet
Entrée Eau Chaude
Entrada Agua Caliente
Check Valve Housing
Logement Clapet Anti-Retour
Sede Válvula Antiretorno
Water Temperature & Pressure Specification
Hot Water Temperature
Maximum: 175°F
Minimum: 50°F higher than maximum required mix water temperature
Recommended: 150°F
Minimum difference between supply hot water and maximum mix temperature: 50°F
Water Pressure
Maximum: 75 PSI
Minimum: 15 PSI
Recommended: 45 PSI
When pressure is higher than 75 PSI you must install an upstream pressure reducer.
Balanced operating pressure on both hot and cold water supplies
grant best thermostatic valve operation and performance.