SAFETY PRECAUTIONS
Only operate the scale in dry locations.
Do not operate the scale in hazardous locations.
Do not drop or overload the scale.
When operating the scale from mains power, only use the AC
Adapter specified by Ohaus.
INSTALLATION
Remove the plastic transportation protective insert (0.1g model
only) for use. Save the plastic insert to ensure safe transport.
See figure 1.
Remove the battery cover on bottom of the scale and insert the
3 LR6 (AA) batteries into the battery compartment. See figure 2.
TWO BUTTON KEYPAD
Press
to turn the scale on.
Long press
to turn the scale off.
Press
to set zero.
Press
to change units.
Long press
to start calibration.
CALIBRATION
1.
Long press
until [CAL] is displayed.
2.
Press
to set the zero point.
3.
When [Cxxx] is displayed, place xxx g weight on the platform.
4.
Press
to set the span point.
5.
After calibration, the display returns to weighing.
Note:
[CAL E] will appear if the calibration steps are not followed or the
wrong weight was used.
Turning the scale off aborts calibration.
MAINTENANCE
The exterior surfaces of the instrument may be cleaned with a
cloth dampened with water and a mild detergent. Do not use
solvents, harsh chemicals, ammonia or abrasive cleaning
agents.
Register your scale under Warranty Registration at
www.ohaus.com/support.
For technical issues contact an Authorized OHAUS Service Agent.
Please visit our website www.ohaus.com to locate the OHAUS
office nearest you.
COMPLIANCE
This product complies with Directives
2011/65/EU (RoHS), 2014/30/EU (EMC) and
2014/35/EU (LVD). The EU Declaration of
Conformity is available online at
www.ohaus.com/ce.
This product complies with the EU Directive
2012/19/EU (WEEE). For disposal instructions
in Europe, refer to www.ohaus.com/weee
en
FCC NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection
against
harmful
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
-
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by OHAUS
Corporation could void the user's authority to operate the equipment.
interference
in
a
residential
Figure 1 / Figura 1 / Figure 1
Figure 2 / Figura 2 / Figure 2
Technical Data / Datos Técnicos / Données Techniques
Models
Max
d
Dirección.
CR221
220 g
0.1 g
Calle UVA 6121
CR621
620 g
0.1 g
CR2200 2200 g
1 g
Cd. Juárez, Chih.
CR5200 5200 g
1 g
Tel.
Ohaus Corporation
Please scan the
• (656) 233 0828
7 Campus Drive
below QR code to
Suite 310
download the user
• (656) 208-3474
Parsippany, NJ 07054 USA
manual:
Tel: +1 973 377 9000 ·
• (656) 655 8604
Fax: +1 973 944 7177
www.ohaus.com
www.mastersupply.com.mx
*30467749*
P/N 30467749 B  2018 Ohaus Corporation, all rights reserved.
Printed in China

Publicité

loading