OPEN WINDOW DETECTION
When the thermostat detects an open window, the
radiator will temporarily go down to anti-freeze mode
and then return to the previous set mode.
LOW SURFACE TEMPERATURE OPTION
If you desire to maximize the radator's surface temperature
to about 60C, press the "fi nger" button (2d) 3 times in less
than 2 seconds, LED2 (2c) should start to fast blinking red
and green. You are allowed to save the surface limitation
option by pressing quickly once again 3 times the "fi nger"
button (2d). Pay attention you only have 5 seconds to save
your choice. After that limitation is activated and LED2 (2c)
is green steady.
If you want to go back to normal surface temperature,
then just repeat the same procedure.
IMPORTANT: This will reduce the maximum heat output
with about 1/3. Must be taken in consideration when for
the heat for the room is calculated.
4. ADVANCED SETTINGS
To enter the tool menu, press "+" and "- " at the same
time for a while, 5 sec. (from
tool menu, press "OK" several times until it is displayed
"End" #9 and the press "+".
TOOL MENU
1. Calibration of temperature sensor on the radiator.
2. Room temperature limitation
3. Pairing Remote control and Thermostat
4. Do not change, should be EXT (shown EHt in display).
5. Calibration of the temperature sensor in the remote
control
6. Not used
7. Not used
8. Software version
9. End (= return to
M16MI38A03_0118_RETTIG_BAYO + THERMOSTAT MILO - 3 LANG.indd 27
mode). To leave the
by pressing "+" or "-")
1. CALIBRATION OF TEMPERATURE SETTING ON
THE RADIATOR
A calibration function is available to ensure that in
optimum thermal conditions the instructions effectively
correspond to the room temperature measured in the
room. However, depending on the particular conditions
of each installation and each room: location, power/
volume, insulation... there could be a gap between the
indication and the temperature measured.
When fi rst starting up adjust your recommended tem-
perature in
comfort mode, then let your installation
adjust itself for a minimum of 4 hours. Then measure the
temperature really achieved and transfer this difference
in temperature to the
installer mode.
1. Press "+" and "-" at the same time for a while, 5 sec.
(from
mode)
2. Position yourself on the "1" segment whose default
value is 0.0 °C
3. Transfer the difference in temperature noted,
(Exemple, you have set the comfort temperature
to 20,0°C and you measure 21,0°C in the room, set
calibration to -1,0°C)
4. Validate by pressing on "OK".
To return to the different operating modes, press "OK"
button a few times until "End" #9 is displayed and the
press "+" button.
2. ROOM TEMPERATURE LIMITATION
To limit the maximum room temperature that will be
possible to set, proceed as follows in
1. Continually press (5 sec.) "+" and "-" simultaneously,
(from
mode)
2. Position yourself on segment "2" whose default value is
30°C.
3. Modify the value by pressing buttons "+" or "-"
4. Validate by pressing on "OK".
To return to the different operating modes, press "OK"
button a few times until "End" #9 is displayed and the
press "+" button.
BAYO - THERMOSTAT
ENGLISH
installer mode.
M16MI384 - A03 - 01/18 | 27
8/01/18 14:24