BAYO - THERMOSTAT
ENGLISH
The radiator should only be switched "on" (2a) when it is
correctly installed and secured to the wall brackets. LED1
(2b) is the heat emitting indicator and it will shine in one
of the below alternatives:
MODE
ELECTRIC HEATING PAUSED
BY THERMOSTAT
Off
Off
Comfort
Green steady light
Reduced
Green blinking light
Anti-freeze
Green double blinking light
Pilot wire,
Green double blinking light
-1°C
Pilot wire,
Green double slowly blinking
-2°C
light
If LED1 (2b) and LED2 (2c) blink slowly green alternatively,
the radiator has not been paired to a Remote Control, go
to "First Start Up and Pairing".
LED2 (2c) is the surface temperature limitation indica-
tor and radio communication indicator (blinking when
communicating) and it should be either off or shining green
continually.
Off
Green steady light
Orange blinking light
IMPORTANT: If your thermostat is turned off, your radiator
will not receive commands from the RF remote control.
TEMPERATURE SETTING AND DESCRIPTION OF
THERMOSTAT MODES
Use the "OK" button to go from one mode to another
(press successively).
NOTE: Whatever the mode, the remote control displays
the room temperature after a few seconds by default.
OPERATING MODE IN
Intended to be used when people are present or likely to
be present in the room. Press buttons +/- to defi ne the
comfort temperature, but it must be higher than the
reduced temperature. If you try to decrease the tempera-
26 | M16MI384 - A03 - 01/18
M16MI38A03_0118_RETTIG_BAYO + THERMOSTAT MILO - 3 LANG.indd 26
ELECTRWIC HEATING ON
BY THERMOSTAT
Off
Red steady light
Red blinking light
Red double blinking light
Green/red double blinking
light
Green/red double slowly
blinking light
Surface temp limitation is off.
Surface temp limitation is on.
RF communication error
COMFORT TEMPERATURE
ture below the reduced temperature, the
The room temperature reappears after a few seconds.
The temperature that you defi ne is the desired tempera-
ture in the room in this mode. You must wait for a few
hours for the temperature in the room to become stable.
When you set the temperature in the comfort mode,
squares will appear in the display below the green/yellow/
red squares. This is a behaviour indicator and it will show
green for temperatures below 19°C, yellow between
19,5°C and 24°C and red above 24°C.
This visual indicator allows the user to be aware of the
risk of excessive energy consumption when setting the
comfort temperature.
OPERATING MODE IN
REDUCED TEMPERATURE
Intended to be used when people are not present, not likely
to be present in the room or if you desire a lower tempera-
ture at night. Press buttons +/- to defi ne the
reduced temperature (limited to 19°C), but it must be lower
than the comfort temperature. If you try to increase the tem-
perature above the comfort temperature, the
The room temperature reappears after a few seconds.
The temperature that you defi ne is the desired tempera-
ture in the room in this mode. You must wait for a few
hours for the temperature in the room to become stable.
OPERATING MODE IN
ANTI FREEZE
This mode prevents the installation from freezing.
It allows a minimum temperature to be preserved during
a prolonged absence. Press buttons +/- to defi ne the
Anti-freeze temperature. The room temperature
reappears after a few seconds.
OPERATING MODE IN
AUTO TEMPERATURE
The Remote control sends the command to follow the
external night reduction to all thermostats paired with it.
1. If the radiator also is paired to Tempco RF clock, the
radiator will follow its commands.
2. If the radiator's control wire is connected, it will
follow the received commands.
> The radiator will follow the Pilot wire commands.
will fl ash.
will fl ash.
8/01/18 14:24