Troubleshooting - HAMPTON BAY HAWKINS YG204-BN-D Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting

WARNING:
Make sure the power is off at the electrical
panel box before you attempt any repairs. Refer to the section
"Making the Electrical Connections" on page 9.
Problem
Problem
The fan will not start.
The fan sounds noisy.
The lights shut off and will
not come back on.
The fan wobbles.
All manuals and user guides at all-guides.com
Solution
Solution
Check main and branch circuit fuses or breakers.
Check line wire connections to the fan and switch wire connections in the switch housing.
Make sure all motor housing screws are snug.
Make sure the screws that attach the fan blade arm to the motor hub are tight.
Make sure wire nut connections are not rattling against each other or the interior wall of the switch
housing.
Allow a 24-hour "breaking-in" period. Most noises associated with a new fan disappear during this
time.
If using the ceiling light kit, make sure the screws securing the glassware are tight. Check that the light
bulb is also secure.
Make sure there is a short distance from the ceiling to the canopy. It should not touch the ceiling.
Make sure your ceiling box is secure and rubber isolator pads are used between the mounting bracket
and outlet box.
This unit is equipped with a wattage limiting device. Lamping in excess of 190 watts will disable your
ceiling fan's light kit. To reset your light kit you must turn the power off and relamp, keeping the
wattage under 190 watts. Restore power to your ceiling fan and continue normal operation.
Check that all blade and blade arm screws are secure.
Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a
point on the ceiling above the tip of one of the blades. Measure from a point on the center of each blade
to the point on the ceiling. Measure this distance. Rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. Measurements deviation should be within 1/8 in. Run the fan for
10 minutes.
Use the enclosed blade balancing kit if the blade wobble is still noticeable.
16

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

752-762

Table des Matières