651 - 652 - 653
q
F- FR - FRL VERSIONS
1/8-1/4 (651) 1/4-3/8-1/2 (652)
ATEX
1/2-3/4-1 (653)
2
EN
FR
DE
651- 652 - 653
ES
IT
NL
NO
SE
FI
DK
PT
GR
CZ
PL
HU
RU
KZ
516682-001
R FR FRL VERSIONS
652 SERIES
q
IN CONFORMITY WITH ATEX DIRECTIVE
Products requiring approval are those that have their own potential ignition risk. These product categories include
and the EC declaration of conformity are provided.
moving parts. They are labelled with the CE marking and the explosion protection hexagon; operating instructions
steam, mists and dust.
These conditioning units of compressed air are envisaged for use in explosive atmospheres in the form of gas,
The classification into zones 1-21 of these units is defined by the following markings: II2GD IIC T85°C (T6) X
4..37
or II2GD IIC T100°C (T5) X.
Compliance with essential health and safety requirements is guaranteed by conformity to the European Standard
EN 13463-1.
This specific ATEX documentation is supplied as an addition to the general user instructions where de-
tailed product information is provided.
______________________________________________________________________________________________
!
SPECIAL CONDITIONS FOR SAFE "X" USAGE :
Ambient temperature range and temperature classification
PRODUCTS:
- REGULATOR
ambient
P1 max.
- MANIFOLD REGULATOR
- AIR PILOT OPERATED REGULATOR
temperature range
(°C)
(bar)
T
T°C
STANDARD
-20 to +50
Low Temperature
-40 to +50
16
T6
85
High Temperature
-20 to +80
16
T5
100
FPM/FKM
-20 to +50
16
T6
85
Low/High Temperature
-40 to +80
16
T5
100
High Temperature + FPM/FKM
-20 to +80
16
T5
100
ambient
P1 max.
- FILTER/REGULATOR
bowl
temperature
range (°C)
(bar)
T
T°C
EN
plastic*
STANDARD
metal
-20 to +50
16
T6
85
Low Temperature
plastic*
metal
-40 to +50
16
T6
85
High Temperature
plastic*
metal
-20 to +80
16
T5
100
FPM/FKM
plastic*
-20 to +50
16
T6
85
plastic*
metal
Low/High Temperature
metal
-40 to +80
16
T5
100
plastic*
High Temperature + FPM/FKM
metal
-20 to +80
16
T5
100
* : Only with manual/semi auto drain.
bowl
temperature
ambient
P1 max.
T
T°C
- COALESCING FILTER/REGULATOR
range (°C)
(bar)
plastic*
STANDARD
metal
+1,7 to +50
16
T6
85
High Temperature
plastic*
metal
+1,7 to +80
16
T5
100
FPM/FKM
plastic*
+1,7 to +50
16
T6
85
metal
plastic*
High Temperature + FPM/FKM
metal
+1,7 to +80
16
T5
100
* : Only with manual/semi auto drain.
3
516023-001
651 + 652 + 653 Series
1
3
2
metal
fi g. A
polycarbonate
3
q
516682-001