iv
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
THE GLOBRITE™ LED LIGHT AND PLASTIC NICHE FORM A COMPLETE NON-
METALLIC LOW VOLTAGE LIGHTING SYSTEM. THIS CONFIGURATION DOES
NOT REQUIRE BONDING OR GROUNDING WHEN POWERED BY A LISTED 100
WATT OR 300 WATT TRANSFORMER (LISTED ON PAGE 19) AND INSTALLED IN
COMPLIANCE WITH THE CURRENT NATIONAL ELECTRIC CODE (NEC).
UNBONDED LIGHTING NEC PROVISIONS: When the UL listed non-metallic
GloBrite LED Light low voltage lights are used with the GloBrite light approved
niches (as listed on page 19), the current NEC provides an exception to
luminaire bonding and grounding in Article 680.6 and 680.23
POOL WATER BONDING NEC PROVISIONS : For Pool Water Bonding required by
NEC Article 680.26C, concrete pools are considered conductive (refer to 680.26
(b)(1) due to the porosity of concrete and the bonding of rebar. No additional
bonding is required.
POOL AND SPA FIXED LUMINARIES: Follow these guidelines when installing or
replacing Pentair Aquatic Systems Pool and Spa fixed luminaries:
FOR LIGHT OPERATION, ONLY USE A SAFETY ISOLATION TRANSFORMER.
Note: Connect both wires to the corresponding circuit wires in the Junction
Box (black wire to power, and white wire to common) FIXED POOL AND SPA
LUMINARIES SPECIFICATION: 12 VAC 50/60 Hz
IMPORTANT NOTICE: THE GLOBRITE LED LIGHT IS A NON-
SERVICEABLE LIGHT. THE COMPLETE LIGHT ASSEMBLY MUST
BE REPLACED.