Option 2: Conduit To Light Niche - Pentair GLOBRITE Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6
Option 2: Install Conduit to Light Niche
To install the conduit onto the GloBrite
1.
Install Sleeve: Locate position on vertical pool or spa wall where light is to
be installed. The top of the light lens must be a minimum of 10.2 cm (4 in)
inches below normal water level. Refer to Figure 2 on page 7 for the exact
depth requirements.
2.
Install a 5 cm (2 in) PVC pipe Schedule 40, 38.1 cm (15 in.) long in the
desired location of the light niche sleeve.
3.
Allow at least 2.5 cm (1 in) of the niche sleeve 5 cm (2 in) PVC pipe to
extend out on both sides of the wall during your gunite operation. Cut any
excess off the pipe so that it is flush against the wall before plastering.
4.
Pull the fish tape and the light power cord through the 2.5 cm (1 in) conduit
and the 5 cm (2 in) PVC sleeve schedule 40.
5.
Glue the 2.5 cm (1 in ) conduit into the back of the conduit shown below in
"Option 2 Installation Diagram".
6.
Glue the cone into gunite niche (the cone is used to guide the fish tape from
the junction box into the niche).
7.
Apply PVC cement to the inside of the sleeve. Slide the gunite niche into the
sleeve until it is flush with the gunite wall.
8.
Install the desired white ring to the front of the niche.
Note: If required by local codes, install the light into niche as described on
page 9.
9.
Using the niche cover to seal the front of the niche, snap on the gunite cover
over the front of the niche. This will protect the light cooling cavity of the
niche during plastering. Note: If a gunite cover is not available, use masking
tape to protect lens and cooling cavity from plaster operation.
10. Apply gunite plaster to pool wall up to the outer edge of the gunite cover. The
gunite cover should be the only exposed part of the niche after plastering.
11. After the plastering has been completed, remove and dispose of the gunite
cover.
Option 2: Conduit to Light - Installation Diagram
GLOBRITE™ White LED Light Installation and User's Guide
All manuals and user guides at all-guides.com
White Light niche:
5.1 cm (2 in) PVC pipe Schedule 40
38 cm (15 IN MIN.)
2.54 cm (1 in) Conduit glue
to Gunite Niche
(Niche Sleeve)
Gunite niche
Color Ring
Gunite Cover

Publicité

Chapitres

Table des Matières
loading

Table des Matières