TH345.01 ITF 24078822 04_06
6.5 - Press button T to confirm
the temperature value indicated on
the display and move on to the
next temperature level, figure 34.
Note. The value which can be assi-
gned to each T level is restricted by
the values of the levels immedia-
tely before and after it, i.e., if level
R
T
T3
T2
T1
R
T
1 2 3 4 5 6 7
18
GB
All manuals and user guides at all-guides.com
T3 is set at 20 °C and level T1 is set
at 16 °C, the value of T2 can only
be set between 16.1 °C and 19.9
°C. In order to achieve a value out-
side this range, e.g., higher than
19.9 °C, you must first change the
value of the adjacent level, e.g.,
increase the value of T3.
6.6 - Repeat steps 6.4 and 6.5 to
vary the values of the other tempe-
1 7
C
0 23
rature levels.
The reappearance of the whole
daily program graph confirms the
end of the temperature level pro-
gramming sequence.
After 10 s without any further ope-
Fig. 34
R
C
1 7
0 23
ON
T3
T2
T1
Fig. 35
11-07-2007
8:21
T
1 7
C
0 23
Fig. 36
Pagina 18
rations being performed, the ther-
mostat abandons the procedure,
retaining the most recent settings.
6.7 - Replace the thermostat
body in its housing.
7 - PERSONALIZING
TEMPERATURE LEVEL
VALUES FOR THE
COOLING PROGRAM
Remove the thermostat body from
its housing. After selecting the
(cooling) operating mode, set the
temperature levels required as
explained from step 6.3 above
onwards. Replace the thermostat
in its housing.
8 - PERSONALIZING
THE DAILY TEMPERATURE
PROGRAM
8.1 - Remove the thermostat
body from its housing.