Standard Programs In Permanent Memory - Bpt TH 345 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TH345.01 ITF 24078822 04_06
from the minutes flash to confirm
the end of the procedure.
In any case, the thermostat auto-
matically abandons this procedure,
memorizing the latest settings, 10
s after the last operation.
3.9 - Replace the thermostat
body in its chassis.
Note. Each time you press
the digits on the display
decrease or increase by one unit; if
you hold the button down, the
digits carry on changing slowly for
the first 5 s, then progress more
rapidly.
R
T
14
GB
All manuals and user guides at all-guides.com
4 - STANDARD
PROGRAMS
IN PERMANENT
MEMORY
4.1 - HEATING PROGRAM
To facilitate the user, the THERMO-
PROGRAM is provided with a per-
manently-memorized heating pro-
or
gram which maintains the tempe-
rature conditions as illustrated in
figure 20 from Monday to Friday
(1÷5) and as illustrated in figure 21
from Saturday to Sunday (6 and
7), in which the temperature levels
are set as follows:
1 7
C
0 23
1 2 3 4 5 6 7
T3
T2
T1
0
Fig. 19
11-07-2007
8:21
ON
4
8
12
16
20
Fig. 20
Pagina 14
T1 16 °C
T2 18 °C
T3 20 °C
4.2 - COOLING PROGRAM
The
permanently-memorized
cooling program maintains the
temperature conditions illustrated
in figure 22, where the temperatu-
re levels are set as follows:
T1 24 °C
T2 26 °C
T2 28 °C
If the permanently-stored pro-
grams coincide with your needs,
1 2 3 4 5 6 7
T3
T2
T1
0
4
8
12
16
20
ON
Fig. 21