APPLICATIONS

Theses submersible motors are used as prime movers of deep well submersible pump
ends used for:
Irrigation, Domestic water supply
Fountains
Industrial water supply
Pressure boosting units
Ponds, Gardens
Sprinkler systems and mining
INSPECTION
Carefully unpack the motor, when it is ready for installation so that it's not damaged or
mishandled. Make sure the details written packing slip and nameplate is according to
the order.
Inspect the motor carefully to make sure no damage has ocurred to the motor, cable and
control box (if any) during transit. You will find label containing name plate details with
an adhesive backing with the motor. The motor is equipped with the electrical cable.
Under no circunstances, the cable should be used to support the weight of the motor or
complete unit.
Only technically qualified personal must perform the works complying with local electri-
cal rules and regulations.

TECHNICAL DATA

Suitable Liquids: These submersible motors must only be used in clean, thin, non-ag-
gressive, non-explosive, clear, cold, fresh water without abrasives, solid particles or fibre
having the following characteristics.
(A) Chlorine ino density
(B) Specific gravity
(C) Hardness (Drinking water)
(D) Viscosity
(E) Turbidity
(F) pH
www.proindecsa.com / proindecsa@proindecsa.com
WARNING !
WARNING !
500 ppm (max.)
1.004 (max.)
200 (max.)
1.75 x 106m2/sec (max.)
50 ppm silica scale (max.)
6.5 to 8.5