SPÉCIFICATIONS D'INSTALLATION (suite)
Drawing Title: LS-B-159-4000-07
INSTALLATION EN PLAQUE D'ÉJECTION
A
NOTES:
1.
EJECTOR AND TRANSFER PIN CONCENTRICITY MUST BE WITHIN 0.030" [0.76] OR
10% OF EJECTOR PIN DIA, WHICHEVER IS SMALLER.
2.
DO NOT SCALE PRINT
3.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
4.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
5.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
20
RJG, Inc.
ANGLES = 3 30
LS-B-159-4000 Single-Channel Sensor Installation—Ejector Plate Installation
A
SECTION A-A
SCALE 1 : 2.5
Top of Mold
LS-B-159-4000 Electronics Housing
Capteur de Bouton de 4 000 Livres à Jauge de Contrainte à Canal Unique Lynx™ LS‑B‑159‑4000 | Manuel du Produit
Description: LS-B-159-4000
Sensor Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 11.18.2021