INSTALLATION MANUAL
1095CFK Circulating Fan Kit
CSA approved for use only with Valor models 1000J Series Heaters
Note: This kit must be installed or serviced by a qualified installer, service agency or
gas supplier. These instructions are to be used in conjunction with the main installation
instructions for the above listed models.
WARNING: If these instructions are not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
GROUNDING: This power supply must be installed and grounded in accordance with local
codes, or in the absence of local codes, with the current Canadian Electrical Code CSA C22.1.
or in the USA the National Electrical Code ANSI/NFPA70 latest edition.
Description of System
The models listed above have been designed to
accommodate the installation of an air circulation fan.
Operated via the remote control handset and having
variable speed control, the fan is designed to boost the
natural convection through the heater; this may be a
desirable feature dependent on the fi replace location
and room layout.
It is preferable to install the circulating fan before com-
pleting the heater installation, although it may also be
retrofi tted at a later date provided power has been pre-
wired within the fi replace casing.
Note: Live wiring must terminate within a junction box.
A junction box is supplied as part of this kit. If roughing-
in power ahead of the fan installation, ensure the wiring
is not live or terminate the wiring within a temporary
junction box.
Retrofi tting the fan after the fi replace installation is
completed will require disconnecting the gas and
removing the burner module and gas train from the
fi replace.
The fan is designed for automatic operation to come
on and off when the burner comes on and off . The
fan speed can be controlled from the remote control
handset. There are four speeds available.
4007549-02
© 2019, Miles Industries Ltd. All rights reserved.
H3 Series
The fan, if turned on, will start approximately 4 minutes
after lighting the appliance and will continue to run for
approximately 10 minutes after the burner is shut off ,
and the control valve has rotated all the way to "OFF".
The fan will operate at the speed last selected by the
user.
Operation
with Valor MAX Remote
Control
To operate the fan, press the "SET" button on
the remote handset until only the fan icon
(
) appears on the display and is fl ashing. Press the
up/down buttons to set the fan speed (
showing means the fan is OFF. Once the fl ashing stops,
the fan is set. The fan icon and number of bars will show
when the remote is in other modes to confi rm the fan
status.
Note: The fan, when plugged in, provides power for
the remote control receiver via the fan control module.
Therefore batteries are no longer required in the battery
holder other than for back-up purposes. Batteries
are still required in the remote control handset.
Electrical Requirements
The fan kit requires a power supply of 120 Volts,
1 phase, 60 Hz. Full load current is less than 1 amp.
MAX
). No bar
1

Publicité

Table des Matières
loading

Sommaire des Matières pour Valor H3 Serie

  • Page 1 H3 Series 1095CFK Circulating Fan Kit CSA approved for use only with Valor models 1000J Series Heaters Note: This kit must be installed or serviced by a qualified installer, service agency or gas supplier. These instructions are to be used in conjunction with the main installation instructions for the above listed models.
  • Page 2 Fan Kits Components Fan control module on mounting plate The complete 1095CFK kit contains the following: • Fan, motor unit, control wire • Fan control module • Electrical junction box cover w/three-prong Adhesive cable retainer receptacle • Wiring diagram label Electrical •...
  • Page 3 b) Do not tighten the wire clamp just yet to allow g) Slide the tab at the far end of the box into for wire adjustment. the slot of the appliance case located right behind the cable clamp. Ensure the wires are not pinched between the junction box and the Approved Wire Clamp...
  • Page 4 5. Apply the self-adhesive wiring diagram label 9. Connect the fan to the receiver. provided to the fan mounting plate between its a) Detach the receiver from the Velcro and plug fixing studs. in the fan control module wire in the 6-pin connection of the receiver as indicated below.
  • Page 5 Finish the fireplace installation Add the 9 V battery to the remote control handset and synchronize the handset to the receiver if it has not 1. Re-attach the burner plate (12 screws). been done yet—see the Installation Manual supplied with the appliance. Fan icon Fan speed icon FASTER...
  • Page 6: Wiring Diagram

    Wiring Diagram Warning—Electrical Grounding Instructions This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and must only be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounded prong from this plug. Spare Parts Code Description...
  • Page 7 Série H3 Ventilateur de circulation d’air 1095CFK Homologué par la CSA pour usage exclusif avec les foyers Valor H3 1000 Note : Ce kit doit être installé et entretenu par un installateur qualifié, une agence de service certifiée ou un fournisseur de gaz. Ces instructions doivent être utilisées conjointement avec les instructions d’installation des modèles mentionnés ci-haut.
  • Page 8: Contenu Du Kit

    Contenu du kit Ventilateur sur plaque de montage Le kit du ventilateur 1095CFK comprend : • Ventilateur, moteur, fil de commande • Module de commande • Boîte de raccordement électrique avec prise 3 Serre-fil broches adhésif • Schéma des connexions •...
  • Page 9 b) Ne serrez pas la bague tout de suite afin de per- g) Insérez la languette de la boîte de raccordement mettre un ajustement. dans la fente située juste derrière la bague de serrage. Assurez-vous que les fils ne soient pas Bague de pincés entre la boîte de raccordement et la paroi serrage...
  • Page 10: Vérifiez L'opération Du Ventilateur

    5. Appliquez le schéma des connexions auto-collant 9. Branchez le ventilateur au récepteur. fourni sur la plaque de montage entre les chevilles a) Détachez le récepteur de ses Velcro et branchez filetées. module de commande du ventilateur à la connexion à 6 broches tel qu’indiqué ci-dessous. Avant de le brancher, assurez-vous que le connecteur est bien orienté.
  • Page 11: Terminez L'installation Du Foyer

    Terminez l’installation du foyer Ajoutez la pile de 9 V à la manette de télécommande et synchronisez la manette au récepteur si cela n’a pas 1. Fixez la plaque du brûleur (12 vis). encore été fait—consultez le Guide d’installation fourni avec le foyer.
  • Page 12: Schéma Des Connexions

    Schéma des connexions Avertissement—Directives de mise à la terre Pour votre protection contre les dangers de chocs électriques, ce ventilateur est équipé d’une fi che polarisée FIL DE MISE À LA TERRE FIXÉ AU VENTILATEUR à trois broches. La fi che doit être branchée directement VENTILATEUR 300 mm LONG dans une prise de courant à...

Table des Matières