3. PROTECTION:
When OVP ,OPP ,OCP,OTP or short protection is triggered, the main outputs will be latched
off. The main outputs can be reset by cycling the DC remote on/off or AC power. +5Vsb
output is auto recovery when fault condition removed.
3.1 OVER VOLTAGE PROTECTION
+3.3V output
4.5 Vmax.
+5.0V output
7.0 Vmax.
+12.0V output 15.6 Vmax.
3.2 SHORT PROTECTION
All output to GND.
3.3 OVER POWER PROTECTION
Foldback at 110%~150% over peak load
3.4 OVER CURRENT PROTECTION
3.5 OVER TEMPERATURE PROTECTION
Protection temperature is 45
4. ENVIRONMENT:
4.1 OPERATING TEMP.
0
to +40
4.2 STORAGE TEMP.
-20
to +70
4.3 OPERATING HUMIDITY
20% to 90%,non-condensing
4.4 STORAGE HUMIDITY
5% to 95%, non-condensing
4.5 OPERATING ALTITUDE
0 to 10,000 feet
4.6 STORAGE ALTITUDE
0 to 50,000 feet