Installations and Connections
Caution:
ONLY CONNECT THIS TO 24 V AC OR 12 V DC CLASS 2 POWER SUPPLY.
The following installation should be made by qualified service personnel or system installers.
I Preparations
Important:
• Procure 4 mounting screws according to the material of the installation area. In this case,
wood screws and nails should not be used.
Recommended tightening torque is as follows.
M4: 1.6 N·m {16 kgf·cm}
• Required pull-out capacity of a single screw/bolt is 196 N {20 kgf} or more.
• If a ceiling board such as plaster board is too weak to support the total weight, the area
shall be sufficiently reinforced.
• The protection sheet attached to the dome cover shall be peeled off after installation.
<Back/upper>
G Direct mounting
If the camera is directly mounted on a
wall/ceiling, align the camera mounting posi-
tion with the position of the hole through
which the cables run and make the hole.
If no hole is made through a wall/ceiling and
open wiring along a wall/ceiling is used,
process the cover so that the cables can be
run through the side of the cover.
Processed section of the side
surface of the cover
46 mm {1-13/16"}
4.5 mm
Side cable access hole
{3/16"}
Camera fixing hole ø4 - 4.5 mm {3/16"}
Cable access hole for wall/ceiling
ø30 - 50 mm {1-3/16" - 2"}
UTP cable access hole
G Using a two-gang junction box
When using a two-gang junction box (4" x
4"), procure one locally that meets the
dimensions in the figure.
And then, locally procure four camera-
mounting screws suitable for the installation
surface and structure of the wall/ceiling or
two-gang junction box.
ø12 mm {1/2"}
11