IFM Electronic AS-i AC1311 Notice De Montage
IFM Electronic AS-i AC1311 Notice De Montage

IFM Electronic AS-i AC1311 Notice De Montage

Contrôleure

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

All manuals and user guides at all-guides.com
Montageanleitung
Installation instructions
Notice de montage
AS-i CONTROLLER
e
CONTRÔLEUR
AS-i
e
AC1311/AC1312

Publicité

Table des Matières
loading

Sommaire des Matières pour IFM Electronic AS-i AC1311

  • Page 1 All manuals and user guides at all-guides.com Montageanleitung Installation instructions Notice de montage AS-i CONTROLLER CONTRÔLEUR AS-i AC1311/AC1312...
  • Page 2: Bestimmungsgemäße Verwendung

    All manuals and user guides at all-guides.com Bestimmungsgemäße Verwendung • Der Controller (AC1311 /AC1312) integriert einen bzw. zwei AS-i Master, beide nach AS-i-Version 2.1, eine Kleinsteuerung und eine CANopen-Schnittstelle • Er steuert den Datenaustausch zur Sensor- /Aktuator-Ebene • verarbeitet die Peripheriedaten im integrierten Prozessor (Signalvor- verarbeitung) •...
  • Page 3: Elektrischer Anschluß

    All manuals and user guides at all-guides.com Elektrischer Anschluß Schalten Sie die Anlage spannungsfrei. Schließen Sie das Gerät entsprechend der Klemmenbeschriftung an. Verbinden Sie nie- mals die Minuspotentiale untereinander oder Minuspotentiale und FE-Anschluß. Stellen Sie eine elektrisch sichere Erdverbin- dung zwischen AS-i Controller (Klemme FE) und Gerät-Erdan- schluß...
  • Page 4 All manuals and user guides at all-guides.com CANopen Status LEDs (Network Status) • LED grün blinkt 1Hz: BUS OFF • LED grün leuchtet: Online, Verbindung o.k. • LED rot blinkt 1Hz: Andere Fehler CANopen Power • LED grün leuchtet: Versorgungsspannung ein •...
  • Page 5 All manuals and user guides at all-guides.com Kontrasteinstellung Sie können den Kontrast direkt durch gleichzeitiges Drücken der rech- ten Taste mit der ∆-Taste (Darstellung ist zu hell) bzw. der ∇-Taste (...zu dunkel) verstellen. ifm electronic ifm electronic Controller E Controller E MENU...
  • Page 6: Menü-Übersicht

    Sie im Startdisplay die Menüpunktes, indem Sie die Tasten ∆ oder ∇ drücken. linke Taste „MENU“ drücken. Drücken Sie die Tasten gleichzei- tig, um zwischen deutschem und englischem Menü zu wechseln. ifm electronic ifm electronic Controller E Controller E MENU USER MENU USER ∆...
  • Page 7 All manuals and user guides at all-guides.com O System Setup (Einstellung des Controller Gerätes) ∇ Baudrate der seriellen Programmierschnittstelle ∇ IP Adresse der Ethernet Programmierschnittstelle (optional) ∇ Eingabe des Passwortes zur Freigabe von Ände- rungen in der Systemkonfiguration ∇ Update der Firmware des Controller (spezielle Programmiersoftware erforderlich) O System Info...
  • Page 8 All manuals and user guides at all-guides.com O Slave Setup (Detaillierte Informationen über die angeschlossenen AS-i Slaves) ∇ Digitale bzw. analoge Ein-/Ausgänge der ange- schlossenen AS-i Slaves ∇ Aktuelle und projektierte Parameter der ange schlossenen AS-i Slaves ∇ Aktuelle und projektierte I/O- ind ID-Codes der angeschlossenen AS-i Slaves ∇...
  • Page 9: Function And Features

    All manuals and user guides at all-guides.com Function and features • The controller (AC1311/AC1312) integrates one or two AS-i masters (both in accordance with the AS-i version 2.1), a mini controller and a CANopen interface • It controls the exchange of data to the sensor /actuator level •...
  • Page 10: Electrical Connection

    All manuals and user guides at all-guides.com Electrical connection Disconnect the installation from power. Connect the unit as indi- cated on the terminals. Never connect the minus potentials to each other or the minus potentials to the FE connection. Ensure an electrically safe ground connection between AS-i controller (terminal FE) and ground of the unit.
  • Page 11 All manuals and user guides at all-guides.com CANopen status LEDs (network status) • LED green flashes 1 Hz: BUS OFF • LED green lights: Online, connection ok • LED red flashes 1 Hz: Other faults CANopen power • LED green lights: Supply voltage on •...
  • Page 12: Contrast Setting

    All manuals and user guides at all-guides.com Contrast setting The contrast can be directly changed by simultaneously pressing the right button and the ∆-button (too bright) or the ∇−button (too dark). ifm electronic ifm electronic Controller E Controller E MENU...
  • Page 13: Menu Overview

    To navigate within a menu point press the button ∆ or ∇. the left button "MENU" in the start display. Press the buttons simultaneously to switch between the German and English menu. ifm electronic ifm electronic Controller E Controller E MENU USER MENU USER ∆...
  • Page 14 All manuals and user guides at all-guides.com O System setup (Setting of the controller device) ∇ Baud rate of the serial programming interface ∇ IP address of the Ethernet programming interface (optional) ∇ Input of the password to enable changes in the system configuration ∇...
  • Page 15 All manuals and user guides at all-guides.com O Slave setup (Details about the connected AS-i slaves) ∇ Digital or analogue inputs/outputs of the connec- ted AS-i slaves ∇ Current and projected parameters of the connec- ted AS-i slaves ∇ Current and projected I/O and ID codes of the connected AS-i slaves ∇...
  • Page 16: Fonctionnement Et Caractéristiques

    All manuals and user guides at all-guides.com Fonctionnement et caractéristiques • Le contrôleur (AC1311 / AC1312) intègre un ou deux maîtres AS-i, les deux selon la version AS-i 2,1, une unité de prétraitement et une interface CANopen. • Il contrôle l'échange de données avec le niveau capteurs / action- neurs, •...
  • Page 17: Raccordement Électrique

    All manuals and user guides at all-guides.com Raccordement électrique Mettre l'installation hors tension. Raccorder l'appareil selon les indications sur les bornes. Ne jamais raccorder les potentiels néga- tifs l'un à l'autre ou les potentiels négatifs à la connexion FE. S'as- surer d'une connexion électrique sûre entre le contrôleur AS-i (borne FE) et la terre de l'appareil.
  • Page 18 All manuals and user guides at all-guides.com CANopen LED d'état (état du réseau) • LED verte clignote 1Hz: Bus non actif • LED verte est allumée: Online, connexion ok • LED rouge clignote 1Hz: D'autres défauts Alimentation CANopen • LED verte est allumée: Tension d'alimentation active •...
  • Page 19: Réglage Du Contraste

    All manuals and user guides at all-guides.com Réglage du contraste Le contraste peut être modifié directement en appuyant simultanément sur le bouton droit et le bouton ∆ (trop clair) ou le bouton ∇ (trop foncé). ifm electronic ifm electronic Controller E Controller E...
  • Page 20: Aperçu Du Menu

    "MENU" dans l'écran de départ. point de menu. Appuyez sur les boutons-poussoirs simultané- ment pour changer entre le menu allemand et anglais. ifm electronic ifm electronic Controller E Controller E MENU USER MENU USER ∆...
  • Page 21 All manuals and user guides at all-guides.com O System Setup (Réglage du contrôleur ∇ Débit de transmission de l'interface de program- mation série ∇ Adresse IP de l'interface de programmation Ethernet (option) ∇ Saisie du mot de passe permettant de modifier la configuration du système ∇...
  • Page 22 All manuals and user guides at all-guides.com ∇ Mise à zéro du compteur config-error ∇ Affichage du taux de défaut en pour cent du système AS-i raccordé O Slave Setup (Informations détaillées sur les esclaves AS-i raccordés) ∇ Entrées/ sorties TOR ou analogiques des esclaves AS-i raccordés ∇...
  • Page 23 All manuals and user guides at all-guides.com Maßzeichnung Scale drawing Schéma d’encombrement PAGE...

Ce manuel est également adapté pour:

As-i ac1312

Table des Matières