Switching On/Off; Operation; Operating Instructions; Air Pressure Test - ULTIMATE SPEED UMK 10 A1 Traduction Du Mode D'emploi D'origine

Mini compresseur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
adapter into the connection
valve hole (7).
- Secure the valve adapter in
the connection valve (7):
push the tensioning lever (8)
towards the connection valve
(position
- Plug the valve adapter into
the valve on the inflatable
item (remove the valve cap
on the inflatable item before-
hand if necessary).

Switching on/off:

5. Switch on the device:
On/off switch (
6. Switch off the device when the desired
fill pressure is reached:
On/off switch (
7. Disconnect the cigarette lighter plug
(
5).
Disconnecting the connection valve:
8. Connection without valve adapt-
er (10):
Open the connection valve (7)
tensioning lever (8) and remove
it from the valve on the inflat-
able item.
Connection with valve adapter
(10):
Remove the valve adapter from
the valve on the inflatable item.
Open the connection valve (7)
tensioning lever (8) and remove
valve adapter.
Air can escape from the valve on the
inflatable item when the connection
valve is released. Ensure that the
connection valve is removed quickly.
The manometer is not calibrated.
After inflating inflatable items on
24
All manuals and user guides at all-guides.com
).
6) in "I" position.
6) in "0" position.
which incorrect pressure may be
dangerous (e.g. tyres), a specialist
unit with a calibrated device should
therefore be visited.

Operation

Operating instructions

The device is not suitable for continuous
operation.
It has been designed to generate air pres-
sure not air volume.
For large-volume items, please do not
operate the device for longer than 5
minutes without interruption, in order
to prevent overheating and damage to
the device. Then allow it to cool for at
least 20 minutes.
We recommend initially filling a large-
volume item with air in order to then
generate the desired pressure with the
device.
Should you require a pressure greater
than 3 bar for a tyre, do not use the
device for longer than 3 minutes with-
out interruption. Then allow it to cool
for at least 20 minutes.

Air pressure test

The device does not need to be
connected to the cigarette lighter in
order to measure the air pressure.
1. Connect the connection valve (7) (see
"Initial operation").
2. Read off the air pressure on the ma-
nometer display (2).
3. Disconnect the connection valve (see
"Initial operation").
The manometer is not calibrated.