Installing and connecting the device
Key:
Symbol
Meaning
lights up constantly
does not light up
➤ Release the
➤ The setting has been saved.
➤ Repeat the procedure to make further settings.
If you switch off the tank monitor with the
be displayed. The settings are not displayed if you switch off the tank monitor
with the external switch.
6.7
Calibrating the tank monitor
I
NOTE
z Calibrate always with empty tank.
z Calibrate the tank monitor once or twice a year.
z If you change the tank material setting, then calibrating will be
required in each case.
z Installing in a boat: During calibration, the engine should be
switched off and the boat positioned as still as possible.
➤ Switch on the power supply.
➤ Press and hold down the
the button.
✓ The calibration starts and is completed in 30 seconds.
The blue LED glows.
6.8
Completing the commissioning
➤ Fill the tank with liquid.
➤ Empty the tank and while doing this carry out several measurements.
➤ Check whether the tank monitor is functioning as required.
32
button.
button until all the LEDs light up, then release
TankMate DTM05C
button, the saved settings will
EN