ELECTRICAL CONNECTION
(only intended for personnel qualiied to install the hood)
Disconnect the equipment from electrical mains power supply before car-
rying out any operations on the hood.
Make sure that the wires inside the hood are not disconnected or cut:
otherwise, contact your nearest Servicing Department.
Refer to qualiied personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.
Before connecting the hood to the electrical mains power supply, check that:
• voltage supply corresponds with what is reported on the data plate located inside the
hood;
• the electrical system is compliant and can withstand the load (see the technical specii-
cations located inside the hood);
• the power supply plug and cable do not come into contact with temperatures excee-
ding 70 °C;
• the power supply system is efectively and properly connected to earth in compliance
with regulations in force;
• the socket used to connect the hood is within reach.
In case of:
• devices itted with cables without a plug: the type of plug to use is a "standardised" one.
The wires must be connected as follows: yellow-green for earthing, blue for neutral and
brown for the phase. The plug must be connected to an adequate safety socket.
• ixed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The yellow/green earth cable must not be cut of by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.
FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are conveyed outside
through the exhaust pipe.
To this end, the hood outlet itting must be connected via a
pipe, to an external output.
The outlet pipe must have:
• a diameter not less than that of the hood itting.
• a slight slope downwards (drop) in the horizontal sections
to prevent condensation from lowing back into the motor.
• the minimum required number of bends.
• the minimum required length to avoid vibrations and reduce the suction performance
of the hood.
You are required to insulate the pipes if it passes through cold environments.
In the presence of motors with 800m
external air lowing back.
Deviation for Germany:
when the kitchen hood is used at the same time as appliances that are powered by energy other
than electricity, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar).
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, air passes through the active carbon ilters (op-
tional) to be puriied and is then recycled into the environ-
ment.
Ensure that the active carbon ilters are assembled onto the
hood, if not, install them as indicated in the assembly in-
structions.
ASSEMBLY INSTRUCTIONS
only intended for personnel qualiied
The hood can be installed in various conigurations.
The generic assembly steps apply to all installations; for each case, follow
the speciic steps provided for the required installation.
All manuals and user guides at all-guides.com
/h or higher, a check valve is present to prevent
3
In this version the check valve must not be assem-
bled: remove it if it is on the air outlet itting of the
motor.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to convey fumes and va-
pours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours.
By means of the Timer function, it is possible to set hood auto switch-of after 15 minutes
of operation.
WHICH SPEED IS TO BE SELECTED?
1
st
speed: maintains the air clean with low electricity consumption.
2
nd
speed: normal conditions of use.
3
rd
speed: presence of strong odours and vapours.
4
th
speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal ilters must be cleaned every 30 hours of operation.
The active carbon ilters (optional), must be replaced every 3-4 months, depending on the
use of the hood.
The HP active carbon ilters (optional), must be reactivated every 3-4 months, depending
on the use of the hood.
For further details see chap. "MAINTENANCE".
USE OF ELECTRONIC PUSH BUTTON CONTROL PANEL
Motor ON/OFF
Upon start-up, the speed is that stored at the previous switch-of.
Speed increase
The 4th speed remains active for a
few minutes.
Speed reduction
The speeds are indicated by the LEDs
on the keys:
Light on/of
TIMER (red LED lashing)
Auto switch-of after 15 min.
The function deactivates (red LED of ) if:
- The motor turns of (key
- The speed is changed (keys +/-).
FILTER ALARM (red LED on)
Anti-grease ilter maintenance after approximately 30 hours of operation.
Press the meter for 3 seconds to reset.
LIGHTING
The range hood is equipped with high eiciency, low consumption LED lighting with extre-
mely long duration under normal use conditions.
In case of failure, contact the Dealer or an authorised Servicing Department for repairs.
17
Speed 1
Speed 2
Speed 3
Speed 4
("+" LED lashing)
).