KeY
ADDITIONAL FUNCTION
K1GR1
+ (PLUS)
K2GR1
- (MINUS)
K3GR1
eNTeR
K5GR1
MeNU
DOSAGe START
by powering the dosage function on the main external switch, the function returns to the "OFF" or "IDLe-ON"
status it was in before the power was cut off (see "Procedures in the event of a power failure").
When the dosage function is powered, the display briefly indicates the version of the software installed (x.yy).
The display shows
OFF STATUS (DOSAGe OFF bUT POWeReD)
With the dosage function off:
- all the outputs are deactivated
- all the functions are deactivated, except for the TeChNICAL LeVeL programming ones
The display shows
Where hh:mm INDICATe the correct time in hours and minutes
N.b. to switch to the OFF status, press the K5GR1 key followed by K3GR1.
To switch to the IDLe ON status, press the K3GR1 key only.
IDLe ON (ON) STATUS
START-UP
To start the dosage, press the K3GR1 key.
In idle-on status, the dosage detects the status of the level and maximum level probes. If the probe detects
that there is not enough water in the boiler, the same is filled automatically by the activation of the filling sole-
noid valve EVliV and of the PUMP until the correct level of water is obtained (Filling time-out - see paragraph
entitled ALARMS).
If the correct levels are detected, or after the topping up of the same, the dosage is set for the activation of the
coffee doses selections or for the programming of the same - where required (see subsequent paragraphs).
the dispensing activation does not depend on the attainment of the set-point temperature in the
boiler.
in iDlE-on StatUS, all tHE lEDS aRE on
The display shows
where hh = current time in hours (0 ÷ 23)
mm = current time in minutes
LA SAN MARCO = customer's name as desired
FUNCTION DeSCRIPTION
Function to "increase" the numerical values or to select default
options related to the parameter being programmed
Function to "decrease" the numerical values or to select default
options related to the parameter being programmed
Function to confirm certain operations during programming
Function to select/choose the parameter you wish to program
LA SAN MARCO
REV.X.YY
OFF
hh:mm
xxx°C
hh:mm
LA SAN MARCO
59