Operating Instructions and Parts Manual
Installation
(Continued)
8. CSECAP40 and CSECAP50 models
are supplied with an "Switch-
Genius" capacative water sensor
(see figure 3B). Position the pump
in the basin so that the "Switch-
Genius" water sensor is 180° away
from the basin inlet. Make certain
the incoming water stream does not
hit the "Switch-Genius" water
sensor surface.
pump from basin for service, always
disconnect electrical power to pump
and control switch. For any work on
pump or switch, ALWAYS unplug the
power cord. Do not just turn off circuit
breaker or unscrew fuse.
Check valve 45
o
TEST
RESET
Inlet
"Switch-
Genius"
surface *
Basin
* Orient the pump so that the "Switch-
Genius" switch surface is 180° away
from the inlet. Make sure the incoming
water stream does not hit the "Switch-
Genius" surface.
Figure 3B - Prefabricated Basins
www.waynepumps.com
Maintenance
that the pump is unplugged before
attempting to service or remove any
component. This pump is assembled in
the factory using special equipment;
therefore only authorized service
dealers or qualified electricians should
attempt to repair this unit. Improper
repair can cause an electrical shock
hazard.
Before
contains oil that may be under pressure
removing
because of heat. Let the pump cool for
a minimum of two hours before
servicing this unit.
1. Disassembly of the motor prior to
expiration of warranty will void the
warranty. It might also cause
internal leakage and damage to the
unit. If repairs are required, return
the pump to the dealer from whom
it was purchased or call 1-800-237-
0987. If motor is ever disassembled
the o-rings must be replaced. Care
must be taken to ensure that all
seals do not leak.
Vent
2. After the basin cover is removed
and necessary discharge piping
disconnected, lift pump from basin.
Gasket
3. Pump should be checked on a
regular basis for proper operation.
If anything has changed since unit
was new, the unit should be
removed and repaired or replaced.
Only qualified electricians or service
people should attempt to repair this
unit. Improper repair and/or
assembly can cause an electrical
shock hazard.
4. Place the pump in a suitable area
where it can be cleaned thoroughly.
Remove all scale and deposits on
pump.
5. Submerge the complete pump in a
Make
certain
6. Clean all dirt and deposits from the
7. Clean all dirt and deposits away
8. Clean "Switch-Genius" water sensor
The
pump
contains dielectric motor oil for
lubrication and motor heat transfer.
This oil can be harmful to the
environment. Check state
environmental laws before disposing of
this oil. This oil can be harmful to
aquatic life so consideration should be
exercised in the application of this
pump.
4
disinfectant solution (10% chlorine
bleach solution) for at least one
hour before handling the pump.
pump float. Make sure float moves
freely after cleaning (CSE50T).
from pump inlet and volute.
surface (models CSECAP40 and
CSECAP50).
This
pump