Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Jet pumps are single stage domestic water
pumps designed for pumping potable water
in applications where the water is up to 100
feet below pump center line. A pressure
switch is a standard feature. A built-in
control valve is available on deep well
pumps. Deep well pumps can be mounted
to either a pre-charged, conventional type,
or free standing pressure tank.
Unpacking
After unpacking the jet pump, carefully
inspect for any damage that may have
occurred during transit. Check for loose,
missing or damaged parts.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates an
imminently hazardous
situation which, if NOT avoided, WILL result
in death or serious injury.
Warning indicates a
potentially hazardous
situation which, if NOT avoided, COULD
result in death or serious injury.
Caution indicates a
potentially hazardous
situation which, if NOT avoided, MAY result
in minor or moderate injury.
Notice indicates
important
information, that if NOT followed, may
cause damage to equipment.
NOTE: Information that requires special
attention.
© 2011, WAYNE/Scott Fetzer Company.
Convertible Well Jet
Pump Water Systems
General Safety
Information
CALIFORNIA PROPOSITION 65
including lead, known to the State of
California to cause birth defects and
other reproductive harm. Wash hands
after handling.
GENERAL SAFETY
1. Read all manuals included with this
product carefully. Be thoroughly
familiar with the controls and the
proper use of the equipment.
2. Know the pump application,
limitations and potential hazards.
to match the system pressure rating and
the maximum flow rate.
or explosive fluids such as gasoline,
fuel oil, kerosene, etc. Do NOT use in
explosive atmospheres. Pump should be
used to pump ONLY clear water. Failure
to follow this warning WILL result in
death or serious injury.
pressure from the system before
attempting to install, service, relocate
or perform any maintenance. Lock the
power disconnect in the open (off)
position. Tag the power disconnect
to prevent unexpected application of
power.
to prevent entrapment of swimmers.
3. Drain all water from the system
before servicing.
4. Periodically inspect pump and
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
5. Personal Safety:
This product
contains chemicals,
6. Do NOT pump chemicals or corrosive
ALWAYS install a
pressure relief valve
7. When installing pump, cover the
Do NOT use to
pump flammable
8. Always test the water from the well
Disconnect power
9. Complete pump and piping system
and release all
10. Do NOT run the pump dry or
Install a screen
around the inlet pipe
installation only. Failure to install
indoors will significantly increase the
risk of injury or death from electrical
shock.
CWS Series
system components. Perform routine
maintenance as required (See
Maintenance, page 6).
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lighted replace all
unused tools and equipment.
c. Keep visitors at a safe distance
from work area.
d. Make the workshop child proof:
use padlocks, master switches and
remove starter keys.
liquids. Pumping these liquids
shortens the life of the pumps seals
and moving parts and will void the
warranty. Pump ONLY clear water.
well to prevent foreign matter from
falling into well and contaminating
the water and damaging internal
mechanical pumping components.
for purity before use. Check with
local health department for test
procedure.
MUST be protected against below
freezing temperatures. Freezing
temperatures could cause severe
damage and void the warranty.
damage will occur and will void
warranty.
This pump is
designed for indoor
340008-001 8/11

Publicité

Table des Matières
loading

Sommaire des Matières pour Wayne CWS Série

  • Page 1 4. Periodically inspect pump and REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. For parts, product & service information © 2011, WAYNE/Scott Fetzer Company. 340008-001 8/11 visit www.waynepumps.com...
  • Page 2: Pre-Installation

    Operating Instructions & Parts Manual General Safety Pre-Installation More usable water is provided than with a conventional type tank. Pre- Information (Continued) WATER SUPPLIES charged tanks are specified in terms of a conventional tank. For example, The water supplies illustrated in Figure All wiring SHOULD a 20 gallon pre-charged tank will have 16 (on page 8) are possible sources for...
  • Page 3 CWS Series Installation DRIVEN WELL (Continued) TO PUMP • Drive the point several feet below the water table. Slope all inlet piping upwards towards WELL the pump to prevent trapping air. NOTE: A packer type foot valve can SEAL Unions or hose couplings can be be installed in the well (Figure 2, installed near pump to facilitate removal Illustration B).
  • Page 4 Operating Instructions & Parts Manual Installation (Continued) CHART 1 - PIPE SIZING Horizontal Distance (Feet) JET BODY 1-1/4 IN. PIPE Pump Pump Model Opening 0-25 26-100 Deep Well Inlet: Suction 1-1/4 in. 1-1/2 in. Inlet: Drive 1 in. 1-1/4 in. 1 IN.
  • Page 5 CWS Series Installation (Continued) Do NOT connect to electric power supply PRIME until unit is permanently grounded. OUTLET PLUG PRESSURE Connect ground wire to approved ground SWITCH then connect terminal provided. SUCTION A metal underground water pipe or well casing at least 10 feet long makes TO JET the best ground electrode.
  • Page 6 Operating Instructions & Parts Manual Operation Protect the pump 1. Test the tank by depressing the air (Continued) from freezing during valve. The air valve will expel water winter conditions. if the bladder is broken. CONTROL VALVE SLOT DRAINING THE PUMP 2.
  • Page 7 CWS Series Maintenance (Continued) ROTATING SEAL MOTOR IMPELLER SEAL PLATE SHAFT SEAL PLATE SEAL MEMBER IMPELLER PUMP PLATE SEAL RUBBER SCREWS HOUSING PLATE SEAT (VOLUTE) RING DIFFUSER SEAL SEAL CERAMIC SEAT FACING SEAT MUST Figure 13 - Removing Shaft Seal and MOTOR BE CLEAN FOR IMPELLER...
  • Page 8 Operating Instructions & Parts Manual www.waynepumps.com...
  • Page 9: Troubleshooting Chart

    CWS Series Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump will not run 1. Power off 1. Turn power on or call power com pa ny 2. Blown fuse or tripped breaker 2. Replace fuse or reset circuit break er 3.
  • Page 10: Replacement Parts List

    For Replacement Parts or Technical Assistance, Call 1-800-237-0987 Please provide following information: Address any correspondence to: - Model number WAYNE Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Page 11 CWS Series Performance Discharge Pressure PSI Suction Model No. Motor HP Lift (Feet) Output in Gallons Per Hour (GPH) CWS50 CWS75 1056 CWS100 Vertical Distance to Pumping Level Pump Model Jet Assembly 100' Jet Diameter Output in Gallons Per Hour (GPH) CWS50 56319 CWS50...
  • Page 12 In no event, whether as a result of breach of contract warranty, tort (in clud ing negligence) or otherwise, shall WAYNE or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equip ment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s cus tom ers for such damages.
  • Page 13 Verrouiller le sectionneur de courant MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. 13-Fr © 2011, WAYNE/Scott Fetzer Company. 340008-001 8/11...
  • Page 14 Instructions D’utilisation et Manual de Pièces Généralités Sur La 17. Utiliser un fil de taille suffisante afin CONTRÔLE DE de réduire la perte de tension au Sécurité (Suite) VOLUME D'AIR moteur. 9. Le système complet de pompe et de NE PAS manipuler tuyaux DOIT être protégé...
  • Page 15: Installation (Suite)

    Série CWS Installation (Suite) source d’eau (Figure 2). Á LA POMPE PUITS FORÉ (FIGURE 16) Cette pompe est conçue pour 1. Installer un clapet de pied sur la JOINT DE l’installation d’intérieur seulement. première section de tuyau (Figure 2, PUITS L’installation en plain air peut augmenter Illustration A).
  • Page 16 Instructions D’utilisation et Manual de Pièces Installation TABLEAU 1 - TAILLES DE TUYAUX (Suite) Distance Horizontale le protéger contre le gel. (Metres) Modèle de Ouverture de Protéger le tuyau contre le dommage Pompe Pompe 0-7,62 7,93-30,5 causé par les nageurs et les bateaux. Puits Profond Arrivée: Aspiration 3,18 cm...
  • Page 17: Électrique

    Série CWS Installation boulons fournis et transforme la pompe (Suite) VIS DE LIGNE pour puits profond en pompe pour puits TERRE 3. Installer une soupape et un tuyau de surface. Le jet pour puits de surface a isolant entre le système et la une arrivée de 1 po NPT et une ouverture tuyauterie de maison afin de faciliter pour un contrôle de volume d’air de 1/8 po...
  • Page 18: Fonctionnement

    Instructions D’utilisation et Manual de Pièces Fonctionnement fonctionnement afin d’éviter le dommage se remplissent d’eau. aux pièces de joints (Voir les sections: 6. Ouvrir la soupape de contrôle REMARQUE: Si la pompe pour puits Amorçage De Pompes Pour Puits De lentement.
  • Page 19: Entretien (Suite)

    Série CWS Entretien (Suite) PLAQUE PLAQUE PIÈCE DE JOINT PLAQUE MOTEUR TURBINE D'ÉTANCHÉITÉ D'ÉTANCHÉITÉ Verrouiller le sectionneur de courant en D'ARBRE D'ETACHÉITÉ ROTATIVE TURBINE position ouverte (arrêt). Étiqueter le BAGUE DE sectionneur de courant pour éviter toute SIÈGE EN mise sous tension imprévue. CAOUTCHOUC 1.
  • Page 20 Instructions D’utilisation et Manual de Pièces 20-Fr...
  • Page 21 Série CWS Tableau de dépannage Symptôme Cause(s) Possible(s) Mesures Correctives La pompe ne 1. Hors Circuit 1. Mettre la pompe en marche ou contacter la compagnie fonctionne pas d’électricité 2. Fusible sauté ou disjoncteur enclenché 2. Remplacer le fusible ou réenclencher le disjoncteur 3.
  • Page 22: Liste De Pièces De Rechange

    Pour pièces de rechange ou assistance technique, appeler 1-800-237-0987 S’il vous plaît fournir l’information suivante: Adresser toute correspondance à: - Numéro de Modèle WAYNE Water Systems - Numéro de série (si présent) 101 Production Drive - Description et numéro de la pièce Harrison, OH 45030 U.S.A.
  • Page 23 Série CWS Performance Hauteur Pression de Décharge kPa d'Aspiration N° de Modèle HP de Moteur (Metres) Debit en Litres Par Heure (L/h) 4091 3000 1855 3,05 3546 2591 1364 CWS50 6,10 3137 2046 9,14 2591 1582 12,19 2073 1227 4501 3546 2100 3,05...
  • Page 24: Garantie Limitée

    Garantie Limitée Pendant trois ans à compter de la date d’achat, WAYNE Water Systems ("WAYNE") va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces de ces Pompes De Puisard ou Pompes À Eau ("Produit") déterminées défectueuses, par WAYNE, soit pour les matériaux ou la fabrication.
  • Page 25 La instalación no en interiores aumenta RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. 25-Sp © 2011, WAYNE/Scott Fetzer Company. 340008-001 8/11...
  • Page 26 Manual de instrucciones de operación y piezas Informaciones Generales la bomba está funcionando en saltos bajos agua. Esta barrera evita que el aire sea (restricción de descarga baja ), voltajes absorbido por el agua y permite que el de Seguridad (Continued) excesivamente altos o bajos, un cableado agua reciba el efecto del aire comprimido...
  • Page 27 Serie de CWS Instalación por lo menos a 45 cm (18 pulg.) del fondo (Continued) A LA BOMBA del pozo de no ser así, PODRÍA aspirar el roscado macho de los tubos de metal. arena o sedimento dentro del sistema. Para los roscados de plástico se debe usar OBTURADOR 4.
  • Page 28 Manual de instrucciones de operación y piezas Instalación (Continued) a menos de 5 pies del fondo del in.) para conectar el tubo más largo pozo, y a que se podría llevar arena y al ensamblado de chorro. tubería de entrada para evitar que sedimento dentro del sistema.
  • Page 29 Serie de CWS Instalación chorro se acopla a la parte frontal de (Continued) VIS DE CONEXIÓN la bomba para pozos profundos con TIERRA separación de la bomba cuando se los dos pernos que se suministran y la le dé servicio, y disminuir el ruido convierte en una bomba para pozo poco transmitido a la casa por la tubería.
  • Page 30 Manual de instrucciones de operación y piezas Instalación La válvula se debe abrir lo más que LA BOMBA (Continued) se pueda sin perder presión. Si a la bomba se le ha dad servicio, se la 6. Deje que el sistema funcione por ha drenado o no se la ha usado por algun 8.
  • Page 31 Serie de CWS Eléctricas 10. Empuje o palanquee el asentamiento pulida del sello. (Continued) de cerámica para separarlo de la 4. Coloque el impulsor en el eje y 4. Si es necesario, ajuste con una placa de sellado (Figura 13). ajústelo bien (Figura 15).
  • Page 32 Manual de instrucciones de operación y piezas 32-Sp...
  • Page 33: Tabla De Identificación De Problemas

    Serie de CWS Tabla de Identificación de Problemas Síntoma Causa(s) Posible(s) Medida Correctiva La bomba no 1. No hay energía eléctrica 1. Encienda la corriente eléctrica o llame a la compañía de funciona suministro eléctrico 2. El fusible se ha quemado o el interruptor se ha 2.
  • Page 34 Llamar al Distribuidor Más Cercano a Su Domicilio Sirvase darnos la siguiente información: Dirija toda la correspondencia a: - Número del modelo WAYNE Water Systems - Código impreso 101 Production Drive - Descripción y número del repuesto según la lista Harrison, OH 45030 U.S.A.
  • Page 35 Serie de CWS Rendimiento Succión de Presión de Descarga bar Elevación 2,07 2,76 3,45 No. de Modelo Motor CP (metros) Entrega en Litros por Hora (LPH) 4091 3000 1855 3,05 3546 2591 1364 CWS50 6,10 3137 2046 9,14 2591 1582 12,19 2073 1227...
  • Page 36: Garantía Limitada

    Bombas de resumideros, Bombas de agua ("Producto") que después de un examen WAYNE encuentre que tenían defectos en su material o mano de obra. Sírvase llamar a la compañía WAYNE (800-237-0987, desde EUA) para recibir instrucciones al respecto o comuníquese con el distribuidor más cercano a su domicilio.

Ce manuel est également adapté pour:

Cws50-1/2 hpCws75-3/4 hpCws100-1 hp

Table des Matières