Les langues disponibles

5. Installation/Commissioning
This product can only be installed by a qualified electrician.
The connection lines in the building must be disconnected before installation and secured against being
switched back on. For this, trip the corresponding fuse switch in the building installation.
Make sure that the surface is suitable for permanently and reliably taking the weight of the light.
Hold the lamp housing at the required assembly position and mark the drill holes. Use appropriate screws
to fix the light. Make sure that no lines are damaged.
Now connect the building installation's connection lines to the screw terminals on the light. Connect the
green-yellow protective conductor first and then the other two cables. The brown (or black) cable is
generally the phase conductor - connect this to the terminal marked with "L". The blue conductor must be
connected to the terminal marked with "N".
Do not bend the cables; make sure that the cables and plugs are not subject to tension or torsional
forces. Protect all cables and insulation against possible damages.
Check proper connection once again.
Switch the building installation's fuse switch back on.
Adjustment of the sensor via the selector switch
Time; Brightness; Range