If the ventilation grille of the air inlet vent cannot be installed flush with the floor of the
niche, you need to install an inlet vent in the floor:
➤ Make an air inlet vent in the floor (fig. 3 6, page 4) behind the refrigerator-oven
combination near the gas burner.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 8, page 6).
6.4
Oven ventilation using a roof flue
A
NOTICE!
• Use a Truma AK 3 roof flue and Truma flue pipes. These have been
tested and approved for use.
• Materials must not be located near the roof flue and flue pipe which
are unsuitable for temperatures of above 120 °C.
• Lay the flue duct so that it rises gradually. The installation height of the
flue pipe between the top of the oven and the air outlet on the roof
flue must be at least 200 mm. A maximum of 1500 mm is possible.
• Keep the surrounding walls and components at a distance of at least
50 mm.
Proceed as follows (fig. 9, page 6):
➤ Make a round hole with a diameter of 60 mm in the roof.
➤ Secure the roof flue (1) in the hole.
➤ Slide the flexible flue pipe (2) up into the roof flue.
➤ Insert the bottom end of the flue pipe (4) onto the end of the flue outlet (5).
➤ Attach the flue pipe using the screws which were supplied with the roof flue (3).
Alternatively, you can use a worm gear hose clamp.
➤ Fit a detachable panel (fig. 3 5, page 4) above the oven.