AERMEC VXT Mode D'emploi page 39

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Visualisation on unit display
A
C o m p r e s s o r 1 O n
P l a n t p u m p
S a n i t a r y p u m p
Parameters that can be modified by the user
Visualisation on unit display
A
P l a n t w a t e r
I n l e t
O u t l e t
D T
Visualisation on unit display
A
S a n i t a r y w a t e r
S a n i t a r y t a n k 4 9 . 5 C
O u t l e t
D T
MAIN menu - PAGE 10
Index
A
B
P 1 0
B
C
0 0 0 %
D D
C
D
MAIN menu - PAGE 11
Index
A
B
B
P 1 1
C
3 0 . 0 C
D
3 5 . 0 C
E
0 5 . 0 C
C
D
E
MAIN menu - PAGE 12
Index
A
B
B
P 1 2
C
D
5 5 . 0 C
E
0 5 . 5 C
C
D
E
Display/Parameter
Compressor 1 ON: Indicates whether compressor 1 is wor-
king, i.e. if the unit is working to satisfy a call.
Page index: Identifies the menu and the corresponding page:
P = MAIN menu
S = SET-POINT menu
M = MAINTENANCE TECHNICIAN menu (Blocked)
C = MANUFACTURER'S menu (Blocked)
CK = CLOCK menu
The number associated to one of the previous codes, indicates
the page of the menu indicated.
System pump: Indicates whether the system pump is active.
DHW pump: Indicates whether the DHW pump is active.
Display/Parameter
System water temperature: Indicates the temperature of the
water produced for the system.
Page index: Identifies the menu and the corresponding page:
P = MAIN menu
S = SET-POINT menu
M = MAINTENANCE TECHNICIAN menu (Blocked)
C = MANUFACTURER'S menu (Blocked)
CK = CLOCK menu
The number associated to one of the previous codes, indicates
the page of the menu indicated.
Inlet water temperature: Indicates the water inlet temperatu-
re at the heat exchanger.
Outlet water temperature: Indicates the water outlet tempe-
rature at the heat exchanger
System Delta T: Indicates the temperature difference betwe-
en inlet and outlet
Display/Parameter
DHW temperature: Indicates the temperature of the water
produced for DHW use.
Page index: Identifies the menu and the corresponding page:
P = MAIN menu
S = SET-POINT menu
M = MAINTENANCE TECHNICIAN menu (Blocked)
C = MANUFACTURER'S menu (Blocked)
CK = CLOCK menu
The number associated to one of the previous codes, indicates
the page of the menu indicated.
Cylinder inlet water temperature: Indicates the water inlet
temperature at the heat exchanger.
Cylinder outlet water temperature: Indicates the water outlet
temperature at the cylinder.
Cylinder Delta T: Indicates the temperature difference betwe-
en inlet and outlet
39

Publicité

Table des Matières
loading

Table des Matières