INSTALLING THE APPLIANCE

WARNING!
The installation and initial start-up of the appliance must be
performed by qualified personnel in compliance with the na-
tional regulations in force regarding installation, and in con-
formity with any regulations issued by local authorities and
public health bodies. The installer is required to observe
the instructions outlined in this manual. Once installation is
complete, it is the installer's duty to inform and instruct the
user on how to operate the water heater and carry out the
main operations correctly.
Transport and handling
Upon delivery of the product, check that the latter has not been
damaged during transport and that no signs of damage appear
on the packaging. In the event of damages, immediately notify
any claims to the forwarder.
WARNING!
THE APPLIANCE SHOULD BE HANDLED AND STORED IN A VER-
TICAL POSITION.
The product may be handled in a horizontal position only for short
distances, while resting on the rear end indicated; in this case, wait
at least 3 hours before starting the appliance once it has been cor-
rectly repositioned in a vertical position and/or installed; this is to
ensure that the lubricating oil inside the refrigeration circuit is suit-
ably distributed and to avoid damages to the compressor.
OK
NOT OK
The packaged appliance may be handled either manually or with the aid
of a forklift truck, while ensuring that the above indications are observed.
It is advisable to keep the appliance in its original packaging until install-
ing it in its chosen location, particularly when construction work is under
way on-site.
When transporting or handling the appliance after the initial installation,
observe the aforementioned indication concerning the allowed tilt angle
and ensure that all water has been drained from the tank. Should the
original packaging be missing, provide an adequate protection for the
appliance to prevent any damages, for which the manufacturer shall not
be held liable.
Location of the appliance
a) In the event of water heaters without an air exhaust duct, the room
of installation should have a volume of no less than 30 m3 and
must be adequately ventilated. Avoid installing the appliance in
rooms which may favour frost build-up.
All manuals and user guides at all-guides.com
b) The appliance's air exhaust and/or extraction duct (if present) must
c) Ensure that the installation site and the electrical and hydraulic sys-
d) The chosen site must have, or must be suitable to house, a sin-
e) The chosen site must be suitable to house a condensate drainage
f) The chosen site must ensure that the appropriate safety distances
g) That installation of the ducts allows maintenance operations on
h) that the plan allows a perfectly vertical operating position;
i) The chosen site must conform to the appliance's IP protection rat-
j) The appliance must not be exposed to direct sunlight, even when
k) The appliance must not be exposed to particularly aggressive sub-
l) The appliance must not be directly installed on telephone lines
m) The appliance must be installed as close as possible to the points
n) The air aspirated by the product must be free of dust, acicid vapours
Leave adequate space around the appliance in order to ensure easy
access and to facilitate maintenance operations. Leave a minimum
distance of 50 cm on both sides of the appliance and the minimum
height from the ceiling should be approximately 20 cm for operation
without air ducts and 23 cm for the operation with air ducts.

Positioning on the ground

1) Once the suitable installation position has been located, remove
2) Using the handles provided, remove the product from the pallet.
3) Fix the feet on the ground (through the appropriate holes) using
Do not install the product in a room containing an appliance that re-
quires air to function (e.g. an openchamber gas boiler, open-cham-
ber gas water heater, etc.) unless otherwise indicated by local law.
The product's safety and performance levels are not guaranteed
in the event of outdoor installation.
have access to the outside from the point where the appliance is
installed. The connections for the air exhaust and aspiration ducts
are located on the upper part of the appliance;
tems to which the appliance must be connected fully comply with the
regulations in force;
gle-phase 220-240 V ~ 50 Hz power supply socket;
outlet connected to the lateral of the appliance with a suitable si-
phon;
observed;
the evaporator filter;
ing (protection against the penetration of liquids) as specified by
the regulations in force;
windows are present;
stances such as acidic vapours, dust or gasfilled environments;;
that are unprotected against overvoltage;
of use to limit heat dispersion along the piping;
and solvents.
min. 200
the packaging and remove the fixings visible on the pallet where
the product is based.
suitable screws and rawlplugs.
3
V > 30m
25 / EN