TIPS FOR USE
LPG CYLINDER USES ADVICES
- The LPG is heavier than air. Any LPG leak may collect in low areas and prevent dispersion.
- The LPG cylinder must be installed, transported and stored in upright position. LGP cylinders should not be
dropped or handled roughly.
- Never place the replacement gas cylinder near the gas fired oven.
- Never store or transport the LGP cylinder in places where temperatures can reach 50°C/112° F (they are too hot
to hold by hand for example: do not leave the LGP cylinder in a car during a hot day).
- Treat "empty" LGP cylinders with the same care as when full. Even when the LGP tank is empty of liquid there
still may be gas pressure in the cylinder. Always close the cylinder valve before disconnecting.
- Be sure the regulator is assembled with the vent hole pointed downward so that it will not collect water. Make
sure the vent hole is free of dirt, grease, insects etc.
- Check all gas connections for gas leak before starting your oven.
- Make sure the valve of the LGP cylinder or regulator is closed. The LGP cylinder must be replaced away from
EN
any source of heat or ignition.
A. Connect the LGP cylinder.
a) Screw the cylinder regulator (NOT included) turning clockwise (1).Position the
regulator so that the vent hole (2) faces down.
b) Screw the gas cylinder regulator turning anti-clockwise (3) (4).
B. Place the cylinder on the floor behind the compartment.
C. Place the LGP cylinder so the valve opening faces to the rear of the oven.
D. Connect the hosepipe (NOT included) to the junction (a) at the back of the oven.
Fix the hosepipe with the included security straps.
Use a pressure control adapter (not supplied) with a flow rate of 10kg/h and G30/
G31 operation at 28..30/37 mbar, utilize a pipe ND 12mm CE EN14800.
- It is advisable to substitute the gas hose every 2-3 years.
- Do not twist the flexible gas hose.
- The length of the flexible hose should not exceed 1,5 m / 59 In.
WHERE TO KEEP THE OVEN
- If the gas fired oven is not used please close the gas cylinder feeding valve.
- If the gas fired oven is stored in an enclosed area, please disconnect the gas feeding. The gas cylinder must be
placed outside in a well aired area.
- If the gas cylinder is not disconnected from the oven, please put them outside in a well aired area.
- The gas cylinder must be placed outside in a well aired place and must be kept away from the children reach.
The unused cylinders must NOT be stored in buildings, garages or other enclosed places.
16
1
2
3
4