5. Special features ZMZ 0215

5.1 Lag time (Option "Q2")

Set the lag-time of the second relay within the menu „Nachlauf" as mentioned above.
Function is deactivated by setting value to „0".
Notice
The lag-relay only needs to be operated with the identical voltage as the main relay
on circuit board. (Also valid for option „C2")

5.2 Advance time (Option "Q1")

Set advance-time within the menu „Vorlauf" as mentioned above.
Function is deactivated by setting value to „0".

5.3 External start / external stop (Option "S")

The functions can be switsched on or off by pushing the „Ändern" button within the
menu „ext. Start" or „ext. Stop". The device is equiped with plug-in for an external
switch on the upper terminal cover if these options are installed. Keep in mind to use
a shielded control cable of max. 3m length to connect the switch.
5.4 Door unlock (Option „M")
To unlock electrical doors of washing machines without insertion of a coin, the device
can be equiped with an additional button. After the basic time passed out, the power
can be switched on again for one minute by pushing the button to open the door.
„Taste/Münze" is diplayed while activated.
5.5 6-digit coin register (Option „A")
Push button „Betrieb" and „Auswahl" to read out the number of inserted coins.
Mz number quantity of inserted coins since last reset,
inserted amount of money at option „O" (tokens ntot added)
GMz number Quantity of all inserted coins since start of operational time
(not resetable)
amount of money at option „O". You can switch between options by
pushing the „Menü" button. Only the Mz Zahl is reset by pushing the
„Ändern" button to request the „Löschen?" display.
5.6 Elapsed time meter (Option „V")
If the device is equipped with option „V" go ahead like described under 5.5. In additi-
on the following registers are displayed:
FSZ
Activation time in hours since last reset
GFSZ
Total activation time since start of operation (not resetable)
Alarm message
In case of jammed coin caused by a cramped cash box „Fehler" is
displayed. Reset the device by pushing the „Betrieb" button longer.