2 INSTALLATION
2C-4. Flow Test - Refer to Figure 3a.
1. Install tube adapter on injector. Use Teflon thread tape as needed.
2. Connect the flow meter assembly to the tube adapter.
3. Hold the flow meter assembly so that the clear plastic chamber is
vertical with the tubing on top.
4. Turn on the pool's circulation system as this allows the injector assembly
to pull a vacuum. Under normal operation, the ball in the flow meter
assembly will be floating in between its Max and Min line. Under worst-
case system conditions the flowmeter ball should indicate at least a
small amount of air flow. Flow may be adjusted as described below.
Manually Adjustable Injector Manifold: Gas flow can be controlled by
adjusting the valve on the manifold. Close the valve to increase gas flow,
open the valve to decrease gas flow.
Self-Adjusting Injector Manifold: This manifold is equipped with a
spring loaded valve. It cannot be manually adjusted, but provides a wide
operating range. If more gas flow is necessary, verify that other valves in
the system are not inhibiting flow through the manifold. If you experience
complications see TROUBLESHOOTING.
Add arrow pointing to
the green square
between the ozone
tubes that says "Check
Valve Assembly"
Check Valve
Ozone Tube
Figure 3b: Ozone Tube Assembly
5
Flow of
Check Valve
Add down arrow here with
the supporting text "Flow of
Check Valve"