4C. Generator Servicing
4C-1. Opening the Unit
The DEL Ozone generator may be serviced on the wall without
disconnecting any of the plumbing or wiring. Simply remove the two screws
on the right side of the enclosure door to open the unit.
4C-2. Ozone Module Replacement
When the green indicator lights go out on the ozone modules, the
corresponding ozone module will need to be replaced.