5 TROUBLESHOOTING
The high concentration of ozone created by the DEL Ozone family
of ozone generators, as well as environmental conditions like UV
sunlight will tend to deteriorate the supplied ozone tube. This is
normal and acceptable, as long as the tubing doesn't become
cracked and leak. Because of this, the ozone tube and check valve
should be replaced every year.
Symptom: Can't get ball to stay in the center of flowmeter.
The flowmeter provided is a general tool to setup flow to the
ozone generator. Flow will vary depending on pressures across the
injector, and therefore can be affected by things such as filter or
strainer loading. The ozone generator's efficiency is optimized near
the center of the flow meter. The DEL Ozone generator will still
perform well at flows above and below the recommended range.
However, the ball must be moving and not stuck on the bottom of
the flowmeter.