6159931360
Issue no: 05
Series: -
I/O EXPANDER CONNECTION
1
2
Legend
1
Termination plug SubD-9pt
2
eBUS cable connection
Put the termination plug when:
- The I/O expander is unique on the
eBUS network.
- The I/O expander is the last
accessory on the eBUS network.

CONTROLLER CONNECTION

● Connect the eBUS cable to the bottom panel
of the controller (see below).
24V-1A is supplied from the controller to
power the I/O expander.
Max current: 400 mA @ 24V DC
Legend
9
Controller eBUS port
All manuals and user guides at all-guides.com
9
I/O EXPANDER POSITION
● By using a screwdriver, select the position
number of the I/O expander on the eBUS
cable: (1-9 and A-F), 1 being the first position,
F the last (F=15).
I/O EXPANDER CONFIGURATION
The I/O expander has 8 Input and 8 Output
which can be configured as standard physical
I/O.
Please refer to CVI CONFIG user's
manual for more information.

LIST OF SPARE PARTS

P/N
Designation
6158121015
Kit of accessories support
1 - Din rail holder + 4 screws
2 - 2 mounting plates
3 - 2 screws M4X10