Fromm & Starck STAR ATFE 05 Manuel D'utilisation page 46

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 88
E08
E11/E21
E13/23
E14/24
E15/E25
E16/E26
E18/E28
E17/E27
E42
E43
with another object - remove objects interfering
with the adjustment.
Danger of collision.
Control box problem - the control box is probably
not positioned correctly. Check that it is firmly
attached to the frame and it is on a level surface,
and that it is not the fault of the cables - if they are
not placed in an orderly manner, they may cause
the box to move.
Disconnecting the cables powering of the lifting
columns - check the connection.
Damage to the lifting columns cables - check and
replace.
E11/13/14 indicates socket M1 error.
E21/23/24 indicates M2 slot error.
Short circuit - replace elements that have shorted
and are no longer usable.
E15 indicates a short circuit in socket M1.
E25 indicates a short circuit in socket M2.
Overload - remove items from the table top.
The frame moves in wrong direction - check lifting
column wiring connection and replace if necessary.
E17 indicates an error in socket M1.
E27 indicates an error in socket M2.
Unable to read the memory - disconnect and
reconnect the power cord. If the problem persists,
replace the control box.
Collision detection system failure - replace the
control box.