Electrical Connection

• Connect the hood to the mains through a two-
pole switch having a contact gap of at least 3
mm.
• Remove the grease filters (see paragraph
Maintenance) being sure that the connector
of the feeding cable is correctly inserted in the
socket placed on the side of the fan.

Chimney assembly

Upper Chimney
• Slightly widen the two sides of the upper flue
and hook them behind the brackets 7.2.1,
making sure that they are well seated.
• Secure the sides to the brackets using the 4
screws 12c (2,9 x 9,5) supplied.
• Make sure that the outlet of the extensions
pieces is aligned with the chimney outlets.
Lower exhaust flue
• Slightly widen the two sides of the flue and
hook them between the upper flue and the
wall, making sure that they are well seated.
• Fix the lower part laterally to the hood body
using the 2 screws 12c (2,9 x 9,5) supplied.
2.1
2
2.2
7.2.1
12c
12c
12c