1. Before hanging the unit on the wall bracket the exhaust/intake transition piece needs to be mounted on the
back of the unit. On the exhaust side of the unit there is a ring that is held on with four screws, it needs to be
removed so the transition piece can be mounted. Use the supplied Phillips head self-tapping screws to attach
the transition piece. Once the transition piece is mounted the ring on the outside of the unit can be put back
on.
2. After you have your hole cut and mounting bracket secured to the wall, the heating unit can hung on the
bracket.
3. Align /intake with the hole in the wall mounting bracket and thimble, and carefully insert heating unit. Tilt the
top of the heating unit towards the wall and lower onto the wall mounting bracket making sure that the right
and left bracket mounted to the unit hooks over the top of the wall mounting bracket. Allow the Heating Unit
to pivot downward becoming parallel to the wall mounting bracket. Lift the unit up and the lower hooks will
engage with the mounting bracket.
4. Once the unit is securely hanging on the wall mounting bracket there are two 7/16" head bolt on the bottom
of the bracket that need to be tightened down to lock the unit to the bracket.
5. Once the unit is locked down the exhaust/ intake pipe can be attached to the unit on the outside of the
house.
VENT TERMINATION CLEARANCES
A. Minimum 4-foot [1.2m] clearance below or beside any
door or window that opens.
B. Minimum 1-foot [0.3m]clearance above any door or
window that opens.
C. Minimum 2-foot [0.6m] clearance from any adjacent
building.
D. Minimum 7-foot [2.1m] clearance from any grade
when adjacent to public walkways.
E. Minimum 2-foot [0.6m] clearance above any grass,
plants, or other combustible materials.
F. Minimum 4-foot [1.2m] clearance from an forced air intake of any appliance.
G. Minimum 2-foot [0.6m] clearance below eves or overhang.
H. Minimum 1-foot [0.3m] clearance horizontally from combustible wall.
NOTICE: This unit shall be installed in such a way that the exhaust gases are
directed so they do not jeopardize people, overheat combustible structures,
or enter buildings. The chimney connector shall not pass through an attic or
roof space, closet or similar concealed space, or a floor, or ceiling. Where
passage through a wall, or partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365, Installation Code for Solid-
Fuel-Burning Appliances and Equipment.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for
damage caused by the malfunction of a heater due to improper venting
or installation. Call (800) 750-2723 and/or consult a professional installer if
A source of fresh air shall be provided when required. To ensure this make
sure that the intake to the concentric vent system is clear of all obstructions
during use. You must use the Duravent FasNSeal Concentric Vent System
designed to work with this appliance from United States Stove Company. DO
NOT substitute other venting systems. The 3" x 5" horizontal square termination
kit (35CVS-KUS) includes:
• 3" x 5" stove adapter
• Adjustable Horizontal Square Cap 35CVS-HZSQ
• Wall Thimble 35CVS-WT
you have any questions.
Venting
-6-
6"
(152 mm)