Maintenance / Cleaning - Delabie TEMPOMATIC 4 NT 430KIT Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
CHARACTERISTICS
Electronic urinal valve:
• The installation must conform to local electrical regulations/standards (in the UK BS 7671, IEE Wiring
Regulations 17th Ed.).
• Recommended pressure 1.5 - 5 bar.
• Flow rate for conventional urinals: 0.15 l/sec at 3 bar.
• Max. flow rate for TEMPOMATIC 4 at 1 bar: 0.37 l/sec. - at 2 bar: 0.52 l/sec - at 3 bar: 0.64 l/sec.
• Calculate the pipe work according to the probable flow rate and the dynamic pressure.
• Connect the TEMPOMATIC 4 to the pipe work using a pipe with a minimum internal diameter of 12mm.
• To avoid interference from infrared beams do not install the electronic mixer or tap opposite a mirror or bright object.
Do not install two electronic mixers or taps opposite each other.
INSTALLATION
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall. DELABIE cannot be held responsible
for any ingress.
In order to comply with WRAS, the installer must ensure that urinal valve is fed by cistern and that there
is a minimum of 1 bar pressure.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
REMEMBER
• Our valves must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
OPERATION OF ELECTRONIC VERSIONS (Fig. U and V)
• Controlled by infrared presence detection: activates after 10 seconds of presence.
• Rinses once the user has departed:
- Short rinse after user departs: 2 sec. or 3 sec. (Fig. U)
- Additional rinse if no further users are detected within 20 seconds: 2 sec., 4 sec. or 8 sec. (Fig. U).
• Choice of programme 1, 2 or 3 depending on desired flush volume and urinal size. During busy periods
only the short rinse takes place between users, the additional rinse takes place after the busy period.
• Hygienic duty flush, every 12 hr, 24 hr (or Off) after the last use: prevents backflow (Fig. V).
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN
EN
12

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tempomatic 4

Table des Matières