Hilti DCG125-S Mode D'emploi page 25

Masquer les pouces Voir aussi pour DCG125-S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
2.10 Using extension cords
Use only extension cords of a type approved for the application and with conductors of adequate cross section. The
power tool may otherwise loose performance and the extension cord may overheat. Check the extension cord for
damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths
Conductor cross
section
en
Mains voltage 100V
Mains voltage 110-
120 V
Mains voltage 220-
240 V
Do not use extension cords with 1.25 mm² or 16 AWG conductor cross sections.
2.11 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this application.
2.12 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit
must provide a power output in watts of at least twice the value printed on the type identification plate on the power
tool. The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in
the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and
starting boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.
2.13 Grinding / cutting discs with Kwik-Lock quick-release clamping nut (optional)
The Kwik-Lock nut can be used instead of the clamping nut. No tools are then required for changing grinding/cutting
discs.
NOTE
Use of the Kwik-Lock nut with cup wheels, slitting discs, brushes, rubber backing pads, tuck pointing discs (special
discs used for joint repair) or with diamond cup wheels is not permissible.
2.14 DG-EX 125/5" dust removal hood for grinding 2
The power tool is suitable only for occasional use with diamond cup wheels for grinding mineral materials.
CAUTION
Use of this guard for working on metal is not permissible.
NOTE
For cutting, grinding and slitting mineral materials such as concrete or stone it is recommended that the dust removal
hood specially designed for the system is used together with a suitable Hilti vacuum cleaner. These serve to protect
the operator and increase the life of the power tool and disc used.
2.15 DC‑EX 125/5"‑M dust removal hood with guide carriage for cutting and slitting 3
Cutting and slitting work on mineral materials may be carried out only when the power tool is equipped with a dust
removal hood with guide carriage.
CAUTION
Use of this guard for working on metal is not permissible.
NOTE
For cutting, grinding and slitting mineral materials such as concrete or stone it is recommended that the dust removal
hood specially designed for the system is used together with a suitable Hilti vacuum cleaner. These serve to protect
the operator and increase the life of the power tool and disc used.
20
All manuals and user guides at all-guides.com
1.5 mm²
2 mm²
30 m
20 m
30 m
50 m
2.5 mm²
3.5 mm²
50 m
40 m
50 m
100 m
14 AWG
12 AWG
75 ft
125 ft

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dag125-sDag125-se

Table des Matières