ORWIRINGWORK ، ‫ﺃﻃﻔﺊ‬
.‫ﻳﺠﺐ ﻋﻠﻴﻚ ﺃﻭ ﻻ ً ﺍﺧﺘﻴﺎﺭ ﺣﺠﻢ ﺍﻟﻜﺎﺑﻞ ﺍﻟﻤﻨﺎﺳﺐ ﻗﺒﻞ ﺗﺤﻀﻴﺮﻩ ﻟﻠﺘﻮﺻﻴﻞ‬
.‫ﻳﺘﻴﺢ ﻛﺎﺑﻞ ﺍﻹﺷﺎﺭﺓ ﺍﻻﺗﺼﺎﻝ ﺑﻴﻦ ﺍﻟﻮﺣﺪﺍﺕ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﺨﺎﺭﺟﻴﺔ‬
:(‫ﺇﺫﺍ ﻛﺎﻥ ﻗﺎﺑﻼ ﻟﻠﺘﻄﺒﻴﻖ‬
H07RN-F
(‫ﻣﺴﺎﺣﺔ ﺍﻟﻤﻘﻄﻊ ﺍﻟﻌﺮﺿﻲ ﻟﻜﺎﺑﻼﺕ ﺍﻟﻄﺎﻗﺔ ﻭﺍﻹﺷﺎﺭﺓ )ﻛﻤﺮﺟﻊ‬
‫ﺍﻟﻌﺮﺿﻴﺔ ﺍﻻﺳﻤﻴﺔ‬
(²‫ﺍﻟﻤﺴﺎﺣﺔ )ﻣﻢ‬
0.75
1
1.5
2.5
4
6
.‫ﻟﻮﺣﺔ ﺍﻻﺳﻢ ﻫﺬﻩ ﻻﺧﺘﻴﺎﺭ ﺍﻟﻜﺒﻞ ﺃﻭ ﺍﻟﻤﺼﻬﺮ ﺃﻭ ﺍﻟﻤﻔﺘﺎﺡ ﺍﻟﻤﻨﺎﺳﺐ‬
‫ﻟﻮﺣﺔ ﺍﻻﺳﻢ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ ﺍﻟﻠﻮﺣﺔ ﺍﻟﺠﺎﻧﺒﻴﺔ ﻟﻠﻮﺣﺪﺓ. ﺍﺭﺟﻊ ﺇﻟﻰ‬
‫ﺣﺴﺐ ﺃﻗﺼﻰ ﺗﻴﺎﺭ ﻟﻠﻮﺣﺪﺓ. ﻳﺸﺎﺭ ﺇﻟﻰ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﻠﺘﻴﺎﺭ ﻋﻠﻰ‬
‫ﻛﺒﻞ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ ﻭﻛﺎﺑﻞ ﺍﻹﺷﺎﺭﺓ ﻭﺍﻟﺼﻤﺎﻡ ﻭﺍﻟﻤﻔﺘﺎﺡ ﺍﻟﻤﻄﻠﻮﺏ‬
22 ‫ﺍﻟﺼﻔﺤﺔ‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻗﺒﻞ ﺃﺩﺍء ﺍﻟﻜﻬﺮﺑﺎء‬
.‫ﺍﻟﻘﻮﺓ ﺍﻟﺮئﻴﺴﻴﺔ ﻟﻠﻨﻈﺎﻡ‬
‫ﺍﻟﺨﻄﻮﺓ 6: ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﻛﺎﺑﻞ ﺍﻹﺷﺎﺭﺓ‬
‫ﺃﻧﻮﺍﻉ ﺍﻟﻜﺎﺑﻼﺕ‬
) ‫ﻛﺎﺑﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﺪﺍﺧﻠﻲ‬
H05VV-F ‫ ﺃﻭ‬H05V2V2-F
:‫ﻛﺎﺑﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﺨﺎﺭﺟﻲ‬
H07RN-F
:‫ﻛﺎﺑﻞ ﺇﺷﺎﺭﺓ‬
‫ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻣﻦ‬
‫ﺍﻟﺘﺼﻨﻴﻒ ﺍﻟﺤﺎﻟﻲ ﻟـ‬
(‫ﺟﻬﺎﺯ )ﺃ‬
6
‫< 3 ﻭ‬
10
‫< 6 ﻭ‬
16
‫< 01 ﻭ‬
25
‫< 61 ﻭ‬
32
‫< 52 ﻭ‬
40
‫< 23 ﻭ‬
‫ﺍﺧﺘﺮ ﻣﻘﺎﺱ ﺍﻟﻜﺒﻞ ﺍﻟﻤﻨﺎﺳﺐ‬
‫ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﺣﺠﻢ‬
‫ﺍﻗﺮﺃ ﻫﺬﻩ ﺍﻟﻠﻮﺍئﺢ ﻓﻲ ﺍﻷﻋﻤﺎﻝ ﺍﻟﻜﻬﺮﺑﺎئﻴﺔ‬
.‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻃﻨﻴﺔ ﻭﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺗﺮﻛﻴﺒﻬﺎ ﺑﻮﺍﺳﻄﺔ ﻛﻬﺮﺑﺎئﻲ ﻣﺮﺧﺺ‬
‫ﺃﻥ ﺗﺘﻮﺍﻓﻖ ﺟﻤﻴﻊ ﺍﻷﺳﻼﻙ ﻣﻊ ﺍﻟﻘﻮﺍﻧﻴﻦ ﻭﺍﻟﻠﻮﺍئﺢ ﺍﻟﻜﻬﺮﺑﺎئﻴﺔ‬
.‫ﺍﻟﻜﻬﺮﺑﺎئﻲ ﺍﻟﻤﻮﺟﻮﺩ ﻋﻠﻰ ﻟﻮﺣﺎﺕ ﺍﻟﻮﺣﺪﺗﻴﻦ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﺨﺎﺭﺟﻴﺔ‬
‫2. ﻳﺠﺐ ﺇﺟﺮﺍء ﺟﻤﻴﻊ ﺍﻟﺘﻮﺻﻴﻼﺕ ﺍﻟﻜﻬﺮﺑﺎئﻴﺔ ﻭﻓ ﻘ ًﺎ ﻟﻤﺨﻄﻂ ﺍﻟﺘﻮﺻﻴﻞ‬
.‫ﻭﺍﺭﻓﺾ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺣﺘﻰ ﻳﺘﻢ ﺣﻞ ﻣﺸﻜﻠﺔ ﺍﻟﺴﻼﻣﺔ ﺑﺸﻜﻞ ﺻﺤﻴﺢ‬
، ‫ﺍﻟﻄﺎﻗﺔ ، ﺗﻮﻗﻒ ﻋﻦ ﺍﻟﻌﻤﻞ ﻋﻠﻰ ﺍﻟﻔﻮﺭ. ﺍﺷﺮﺡ ﺃﺳﺒﺎﺑﻚ ﻟﻠﻌﻤﻴﻞ‬
‫3. ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻮﺩ ﻣﺸﻜﻠﺔ ﺧﻄﻴﺮﺓ ﺗﺘﻌﻠﻖ ﺑﺎﻟﺴﻼﻣﺔ ﺑﻤﺼﺪﺭ‬
.‫ﻛﻔﺎﻳﺔ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ ﺇﻟﻰ ﺣﺪﻭﺙ ﻋﻄﻞ ﺃﻭ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎئﻴﺔ ﺃﻭ ﻧﺸﻮﺏ ﺣﺮﻳﻖ‬
‫ﻳﻜﻮﻥ ﻓﻲ ﺣﺪﻭﺩ 09-011٪ ﻣﻦ ﺍﻟﻔﻮﻟﻄﻴﺔ ﺍﻟﻤﻘﺪﺭﺓ. ﻳﻤﻜﻦ ﺃﻥ ﻳﺆﺩﻱ ﻋﺪﻡ‬
.‫ﻭﻣﻔﺘﺎﺡ ﻃﺎﻗﺔ ﺭئﻴﺴﻲ ﺑﺴﻌﺔ 5.1 ﻣﺮﺓ ﻣﻦ ﺃﻗﺼﻰ ﺗﻴﺎﺭ ﻟﻠﻮﺣﺪﺓ‬
‫ﺍﻟﻄﺎﻗﺔ ﺑﺄﺳﻼﻙ ﺛﺎﺑﺘﺔ ، ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﻭﺍﻗﻲ ﻣﻦ ﺯﻳﺎﺩﺓ ﺍﻟﺘﻴﺎﺭ‬
.‫ﺍﻟﺜﺎﺑﺘﺔ. ﻳﺠﺐ ﺃﻥ ﻳﺴﺘﺨﺪﻡ ﺍﻟﻔﻨﻲ ﺍﻟﻤﺆﻫﻞ ﻗﺎﻃ ﻌ ًﺎ ﺃﻭ ﻣﻔﺘﺎ ﺣ ًﺎ ﻣﻌﺘﻤ ﺪ ًﺍ‬
‫ﻭﻟﺪﻳﻪ ﻓﺎﺻﻞ ﺗﻼﻣﺲ ﻻ ﻳﻘﻞ ﻋﻦ 8/1 ﺑﻮﺻﺔ )3 ﻣﻢ( ﻓﻲ ﺍﻷﺳﻼﻙ‬
‫ﺛﺎﺑﺘﺔ ، ﻳﺠﺐ ﺩﻣﺞ ﻣﻔﺘﺎﺡ ﺃﻭ ﻗﺎﻃﻊ ﺩﺍئﺮﺓ ﻳﻔﺼﻞ ﺟﻤﻴﻊ ﺍﻷﻗﻄﺎﺏ‬
‫ﺍﻟﻮﺣﺪﺓ ﺑﻤﺄﺧﺬ ﺍﻟﺪﺍئﺮﺓ ﺍﻟﻔﺮﻋﻴﺔ ﺍﻟﻔﺮﺩﻱ ﻓﻘﻂ. ﻻ ﺗﻘﻢ ﺑﺘﻮﺻﻴﻞ ﺁﺧﺮ‬
.‫8. ﺗﺄﻛﺪ ﻣﻦ ﺗﺄﺭﻳﺾ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﺑﺸﻜﻞ ﺻﺤﻴﺢ‬
.‫ﺍﻟﺠﻬﺎﺯ ﺍﻟﻄﺮﻓﻴﺔ ، ﻣﻤﺎ ﻳﺆﺩﻱ ﺇﻟﻰ ﺣﺪﻭﺙ ﻋﻄﻞ ﺑﺎﻟﻤﻨﺘﺞ ﻭﺍﺣﺘﻤﺎﻝ ﻧﺸﻮﺏ ﺣﺮﻳﻖ‬
‫ﺳﻠﻚ ﺑﺈﺣﻜﺎﻡ. ﻳﻤﻜﻦ ﺃﻥ ﺗﺘﺴﺒﺐ ﺍﻷﺳﻼﻙ ﺍﻟﻔﻀﻔﺎﺿﺔ ﻓﻲ ﺍﺭﺗﻔﺎﻉ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ‬
.‫ﺿﺪ ﺃﻧﺎﺑﻴﺐ ﻏﺎﺯ ﺍﻟﺘﺒﺮﻳﺪ ﺃﻭ ﺍﻟﻀﺎﻏﻂ ﺃﻭ ﺃﻱ ﺃﺟﺰﺍء ﻣﺘﺤﺮﻛﺔ ﺩﺍﺧﻞ ﺍﻟﻮﺣﺪﺓ‬
.‫ﻋﻠﻰ ﺑﻌﺪ ﻣﺘﺮ ﻭﺍﺣﺪ ﻋﻠﻰ ﺍﻷﻗﻞ )04 ﺑﻮﺻﺔ( ﻣﻦ ﺃﻱ ﻣﻮﺍﺩ ﻗﺎﺑﻠﺔ ﻟﻼﺣﺘﺮﺍﻕ‬
‫ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻮﺣﺪﺓ ﺗﺤﺘﻮﻱ ﻋﻠﻰ ﺳﺨﺎﻥ ﻛﻬﺮﺑﺎئﻲ ﺇﺿﺎﻓﻲ ، ﻓﻴﺠﺐ ﺗﺮﻛﻴﺒﻬﺎ‬
.‫ﺍﻧﺘﻈﺮ ﺩﺍئ ﻤ ًﺎ 01 ﺩﻗﺎئﻖ ﺃﻭ ﺃﻛﺜﺮ ﻗﺒﻞ ﺃﻥ ﺗﻠﻤﺲ ﺍﻟﻤﻜﻮﻧﺎﺕ ﺍﻟﻜﻬﺮﺑﺎئﻴﺔ‬
، ‫ﻓﺘﺮﺓ ﻭﺟﻴﺰﺓ ﻣﻦ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ. ﺑﻌﺪ ﻓﺼﻞ ﺍﻟﻄﺎﻗﺔ‬
‫ﺍﻟﺘﻌﺮﺽ ﻟﺼﺪﻣﺔ ﻛﻬﺮﺑﺎئﻴﺔ ، ﻻ ﺗﻠﻤﺲ ﺍﻟﻤﻜﻮﻧﺎﺕ ﺍﻟﻜﻬﺮﺑﺎئﻴﺔ ﺑﻌﺪ‬
‫ﻗﺒﻞ ﺃﺩﺍء ﺃﻱ‬
‫1. ﻳﺠﺐ‬
‫4. ﺍﻟﺠﻬﺪ ﺍﻟﻜﻬﺮﺑﺎئﻲ ﻳﺠﺐ ﺃﻥ‬
‫5. ﻓﻲ ﺣﺎﻟﺔ ﺗﻮﺻﻴﻞ‬
‫6. ﻓﻲ ﺣﺎﻟﺔ ﺗﻮﺻﻴﻞ ﺍﻟﻄﺎﻗﺔ ﺑﺄﺳﻼﻙ‬
‫7. ﻗﻢ ﺑﺘﻮﺻﻴﻞ‬
.‫ﺟﻬﺎﺯ ﻟﻬﺬﺍ ﺍﻟﻤﻨﻔﺬ‬
‫9. ﻳﺠﺐ ﺗﻮﺻﻴﻞ ﻛﻞ‬
‫01. ﻻ ﺗﺪﻉ ﺍﻷﺳﻼﻙ ﺗﻠﻤﺲ ﺃﻭ ﺗﺴﺘﺮﻳﺢ‬
‫21- ﻟﺘﺠﻨﺐ‬
.11