External hous-
Cleaning
ing and front
panel
Water outlet
Disinfection
parts
Drip tray and
Cleaning
grid
Emptying
Ventilation
Cleaning
slots
Water circuit
Disinfection
in the water
dispenser
Filter
Replacement
CO
safety
Check the gas
2
check
pressure reducer
and check the
entire device
for leaks
UV reactor/
Visual inspection
quartz glass
for contaminants
or cloudiness on
the quartz glass
* six-monthly or when capacity is used up
** or every 2 years
36
All manuals and user guides at all-guides.com
daily
weekly
six-monthly
annually
Customer/operating
company (remove lime
marks from the surface
of the device using a
descaling spray and
then clean and disin-
fect using a sanitary
spray)
Customer/operating
company (clean and
disinfect using a sani-
tary spray)
Customer/operat-
ing company (under
running water with
standard mild cleaner)
Customer/operating
company
Technical staff of
the distributor or
authorised, qualified
technical staff
Technical staff of
the distributor or
authorised, qualified
technical staff
Technical staff of
the distributor or
*
authorised, qualified
technical staff
Technical staff of
the distributor or
authorised, qualified
**
technical staff (only by
competent person)
Technical staff of
the distributor or
authorised, qualified
technical staff (only by
competent person)
» Clean the water outlet area including the drip tray with the sanitary spray and then wipe dry
with a cloth.
» Spray the entire water outlet area daily using the sanitary spray, allow it to act for 30 seconds
and dry with a clean cloth.
» The maintenance interval is dependent on the amounts of water dispensed (pay attention to
the filter capacity) and local conditions. We recommend having the water dispenser disinfect-
ed and the water filter replaced by qualified personnel at least every six months.
For proper hygiene, the AQA drink Pro 20 water dispenser should be cleaned weekly by a re-
sponsible, trained person.
37