Scope of supply
3.1 Basic device
Hydraulic components
Dual differential pressureless manifold
Buffer tank 210 litres
Unmixed heating circuit incl. controlled circulating pump
(infinitely variable or 3 stages), shut-offs and back-pressure
feature
Primary circuit heat generation incl. circulating pump (3
stages, shut-offs
2. Heat generator, electrical pipe heater, heat output from 2,
4 to 6 kW, secured via safety temperature limiter
Technical safety equipment:
Pressure gauge
Safety valve, start-to-leak pressure 2.5 bar
Diaphragm expansion vessel 24 litres
An additional expansion vessel can be connected
3.2 Switch box
ATTENTION!
Before opening the device, ensure that all circuits are isolated from the
power supply.
The switch box is located in the upper area of the hydraulic
tower. After removing the lower and upper front panels, the
switch box can be freely accessed and, by loosening the two top
mounting screws, it can be folded open.
The switch box contains the supply connection terminals, heating
contactors, umbilical cable connections (connecting line to the
heat pump) and the heat pump controller.
3.3 Heat pump controller
The integrated heat pump manager is a convenient electronic
regulating and control device. It controls and monitors the entire
heating system on the basis of the external temperature, includ-
ing domestic hot water preparation and safety systems.
The customer must install the external temperature sensor,
which is included in the scope of supply of the heat pump control-
ler together with the necessary fixing accessories.
The enclosed operating instructions describe the function and
use of the heat pump manager.
All manuals and user guides at all-guides.com
4
Transport
Use a wooden pallet for transporting the heat pump to the final in-
stallation location. The basic device can be transported with a lift
truck, hand truck or by means of 3/4" pipes fed through the holes
in the base plate or frame.
ATTENTION!
The hydraulic tower and transport pallet are only connected by the
packing film.