CLEANING
CAUTION! Disconnect the unit from the AC
adapter and cap AC adapter socket before
cleaning. Do not use with pressure washers or
other high pressure water jets. Rated IP65 for
use with hoses.
Use a mild detergent for the display and keypad.
WARNING! Do not use solvents, chemicals,
alcohol, ammonia or abrasives.
ERROR
Inaccurate weights
Err 4
Err 6
-OL-
Bat lo
If the problem persists or the troubleshooting section does not resolve or describe your problem,
contact Uline Customer Service at 1-800-295-5510.
PAGE 12 OF 36
MAINTENANCE
TROUBLESHOOTING
OPERATING ISSUE
Shipping screw needs to be removed.
Scale needs to be recalibrated.
Scale needs to be recalibrated.
Load cell connectivity issue.
AD board connectivity issue.
Maximum capacity exceeded.
Battery needs to be recharged.
1-800-295-5510
uline.com
Use a stainless steel cleaning solution for the stainless
steel indicator housing and platform.
Apply cleaner to a clean, damp cloth and wipe surface.
Dry thoroughly.
RECOMMENDATIONS
Remove shipping screw.
Recalibrate the scale.
Recalibrate the scale.
Verify all load cell connection wires are secure.
Verify all AD board connection wires are secure.
Remove load from platform.
Recharge battery.