Measuring station
6.2 Pin allocation table
Digital
Function
SysLink
I0
13
I1
14
I2
15
I3
16
I4
17
I5
18
I6
19
I7
20
Q0
1
Q1
2
Q2
3
Q3
4
Q4
5
Q5
6
Q6
7
Q7
8
24 V A
9+10
24 V B
21+22
GND A
11
GND A
12
GND B
23+24
Note
Cable jumpers are connected from emergency off to bit 1.5 on all PLC variants.
32
Colour
Designation
Grey-pink
Workpiece at start of conveyor
Red-blue
Workpiece at intermediate conveyor position
White-green
Workpiece not at end of conveyor
Brown-green
Distance sensor (switching output signal)
White-green
Gripper open
Brown-yellow
Gripper raised
White-yellow
Swivel module in position "Conveyor"
Grey-brown
Swivel module in position "Measuring table"
White
Conveyor forward
Brown
Conveyor reverse
Green
Advance deflector
Yellow
Retract stopper
Grey
Open gripper
Pink
Gripper downwards
Blue
Turn swivel module to position "Measuring table"
Red
Black
24 V power supply for outputs
White-pink
24 V power supply for inputs
Brown-pink
0 V power supply for outputs
Purple
0 V power supply for outputs
White-blue
0 V power supply for inputs
© Festo Didactic 8103339