Perform the following test to check for damage to the ceramic
plates inside the stop unit.
Failure to correctly perform this test can result in possible water
damage.
Turn on the water supplies. Grasp the stop unit
and turn it.
If there is a leak around the cartridge, turn the
supplies off, and remove the cartridge. Confirm
that the sealing gasket from the flushing plug was
removed.
Reinstall the cartridge. Turn the stop unit.
If the unit continues to leak, contact
Hansgrohe Customer Service for a re-
placement cartridge.
Install two Duotec strips directly on the carrier
plate. Install the remaining two strips on the back
of the escutcheon.
Install the carrier plate and gasket with the carrier
plate screws.
Press the escutcheon firmly over the carrier plate.
The strips of Duotec will interlock, producing a
very firm hold.
Install the handle. Tighten the handle screw with
a 3 mm Allen wrench. The handle screw must
engage the slot milled into the brass on the bottom
of the cartridge.
Set the high temperature limit stop (optional) – see
page 11.
Justify the handle.
English