Télécharger Imprimer la page

Novy 7240400 Instructions D'installation page 6

Masquer les pouces Voir aussi pour 7240400:

Publicité

Les langues disponibles

Les langues disponibles

Carefully read these instructions before installing this device and putting it into operation. It is recommended to have
the installation carried out by a qualified person. The manufacturer will not accept any liability for damage caused by
installation not in accordance with the instructions or by improper installation. Check the status of the device and the
mounting materials as soon as you have unpacked them. Carefully remove the device from the packaging. Do not use
sharp knives to open the packaging.
Turn off the hood power supply in the switch box.
1
Remove the protective film from the ceiling plate (A). Orient the ceiling plate of your choice (the longest side = longest
2
side of the hood) and attach it to the ceiling using screws (C) and/or plugs (B). Feed the electrical supply cable (F)
through the opening provided for it in the ceiling plate (A)
Remove the bolts on the suspension frame (E) and slide the suspension frame (E) upwards until it is completely loose.
3
Assemble suspension frame (E) against the ceiling plate (A) with the spacers (D) between them and attach with the
screws (C) (supplied with the hood) to the ceiling.
Insert the noise damper (G) as close as possible to the ceiling plate (A) in the suspension frame (E) and fasten with
4
screws (H) Feed the electrical supply cable (F) through the underside of the noise damper (G) and fit the connection
power socket (K)
Mount the hood on the suspension frame (E) at the desired height using the nuts and bolts. The correct 8 bolts (H)
5
must be used.
Mount the exhaust tube (L) to the noise damper (G) and to the motor. Cut the supplied insulation to size and attach
6
it around the exhaust using tape.
7
Connect the hood power socket to the power supply connection power socket.
Screw to the chimney with stainless steel screws (J).
8
9
You can now enable the power by switching it on in the electrical switch box.
Mounting the Monoblock filter:
Remove the Monoblock filter (D) from the Monoblock filter holder (A). Press the lock spring (B) lightly together between
A
your thumb and index finger to unlock it.
Open the lower plate and remove the grease filter from the hood. Take the Monoblock filter holder (A) and place it in
B
the hood by releasing the spring on the hinge side of the lower plate and fasten with 6 screws (C).
Put the Monoblock filter (D) back in the Monoblock filter holder.
C
Close the lock spring (B) by squeezing it together and securing it in the slot provided. Put the grease filter
D
(E) back in the hood. You can re-open the lock spring(s) by squeezing them together and pulling them
rearwards.
Programming a saturated carbon filter (Caution: carry out the programming with the motor disabled):
Operation: Simultaneously press + and – for 5 sec. until the red LED flashes 3 times.
• The run-out time has now been set to 30 minutes (instead of 10 min.).
• The saturated carbon filter indicator has been set (200 operating hours).
The red LED will light up after 200 working hours (time to regenerate the used Monoblock).
Reprogramme: simultaneously press + and – for 5 sec. until the red LED flashes 3 times for confirmation.
(if this programming is not carried out, the programming is automatically set after the device has been switched on 10
times.)
• Disable the programming: Simultaneously press + and – for 5 sec. until the third green LED flashes 3 times.
Clean the monoblock filter:
• The Monoblock filter can be regenerated up to 12 times. This is carried out in the oven.
• Place the filter in the oven for 1 hour at 120°C. Provide sufficient fresh air in the room where the oven has been
placed, as smells can be released.
• Smells can be released when baking certain kinds of fish. The best solution is to immediately regenerate the filter.
All manuals and user guides at all-guides.com

Publicité

loading

Ce manuel est également adapté pour:

7240400/1