Keypad Zone; Keypad Zone Requires 1Kw Eol Resistor - Paradox Security Systems ESPRIT 642BL Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Keypad Zone

Section [2] — Option [1]
Off = Disabled
On = Enabled (default)
This option enables/disables the keypad's on-board zone. Only two
keypad zones are available on an Esprit control panel, and only one
on-board zone per keypad.
Keypad Zone Requires 1k
Section [2] — Option [2]
= No (default)
Off
= Yes
On
When option [2] is off, you do not need to install an EOL resistor.
When option [2] is on, you must install an external 1kΩ EOL resistor
as shown in Figure 1 on page 29.
Keypad Zone Set To Zone 1/Zone 2
Section [2] — Option [3]
Off = Keypad Zone 1 (default)
On = Keypad Zone 2
The Esprit system supports two keypad zones, and this option
determines whether the on-board keypad zone input is identified as
keypad zone 1 or keypad zone 2.
Ω
EOL Resistor
Esprit+ (642BL) 5