Scrolling Zone Display shows the zone label and status of one zone
per screen. If zone 3 was open, the screen would read: zones
open [3] zone label
.

Display AC Status on LCD Screen

Section [2] — Option [
] = C
FORCE
Off = Yes (default)
On = No
This option, when enabled, displays
or
on the lower
AC
No AC
right-hand side of the screen, indicating whether the panel is
connected to the AC supply or not. It is recommended that you turn
on the option (No) for the 748/748ES panels since they do not
support this function.

Time Format

Section [2] — Option [BYP] = D
= International 24-hour clock (default)
Off
On = U.S. 12-hour clock
The 642BL LCD Keypad can display the time using the 24-hour clock
(option [D] off) or using the 12-hour (US) clock with the
and
AM
PM
indications (option [D] on).
• 18:00 = International (option [D] off)
• 6:00 pm = U.S. (option [D] on)

Backlight Functionality

When the system is Stay or Instant armed, the intensity of the
keypad's backlight automatically decreases to a Level 1 setting.
During this time, if a key is pressed on the keypad, the backlight
switches to regular intensity and then returns to the Level 1 setting
when all actions on the keypad cease. The backlight returns to
regular intensity when the system is no longer Stay or Instant armed.