.
6-3/4 (171)
Media Replacement:
Replace the filter at least annually or when the built-in pressure
sensors in the F200 door detect that airflow is impaired and the
filter requires cleaning. This condition causes the indicator light
on the F200 door to begin flashing and the transmitter to send
a signal to the wall-mounted RF Indicator that the filter needs
replacing.
After replacing the filter, press the reset button on the F200
door to reset both the door indicator light and the RF
AIRWATCH® Air Cleaner Indicator. See Fig. 2. (See Table 1
for AIRWATCH® operation.)
DIM. A
(SEE
TABLE)
7/8
(22)
5/8
(16)
2-1/2
(63)
F200E SIZE
IN.
MM
16 X 25
406 X 635
16 X 20
406 X 508
20 X 25
508 X 635
20 X 20
508 X 508
Fig. 1. Installation dimensions in in. (mm) of air cleaner.
DIM. C (SEE TABLE)
DIM. D (SEE TABLE)
DIM. A
DIM. B
IN.
MM
IN.
MM
14 7/16
367
16 3/16
411
14 7/16
367
16 3/16
411
18 7/16
468
20 3/16
513
18 7/16
468
20 3/16
513
Fig. 2. RF transmitter door - interior view.
3
F200 CHARGED-MEDIA AIR CLEANER
1-1/8 (29)
DIM. B
(SEE TABLE)
7/8
(22)
DIM. D
DIM. C
IN.
MM
IN.
MM
23 1/4
591
25
648
18 1/4
457
20
521
23 1/4
591
25
648
18 1/4
457
20
521
M14784A
BACK SIDE OF DOOR
RESET BUTTON
BATTERY
M14864
68-0238EF—04