APPLICATION
The F200 Charged-Media Air Cleaner captures a significant
amount of the air-borne particles from the air circulated
through the unit.
FEATURES
• Charged-Media filter captures particles as small as 0.3
micron.
• Efficiency ratings based on the American Society of
Heating, Refrigerating and Air Conditioning Engineers
Standard 52.2-1999.
• Applicable to all gas, oil, and electric forced warm air
furnaces and to compressor cooling up to 5 tons.
• Mounts in the return air duct.
• Cabinet can support weight of residential furnace and
evaporator coil.
• Requires no electrical connections.
• Mounts in any position.
• Requires no maintenance except periodic battery and
media filter replacement.
• Quick and easy media filter replacement.
• Later upgrade to electronic air cleaner is easy.
• Integral pressure sensors signal when filter change is
required based on increased pressure drop threshold
at filter.
• Filter change status is transmitted to wall-mounted
AIRWATCH® Indicator.
• The RF AIRWATCH® Indicator is included.
Application/Features .........................................................
Specifications/Ordering Information .................................
Installation and Checkout .................................................
Checkout ..........................................................................
F200E Parts List. .............................................................. 10
PRODUCT DATA
Contents
1
2
7
8
68-0238EF-04

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell F200

  • Page 1 F200 Charged-Media Air Cleaner PRODUCT DATA APPLICATION The F200 Charged-Media Air Cleaner captures a significant amount of the air-borne particles from the air circulated through the unit. FEATURES • Charged-Media filter captures particles as small as 0.3 micron. • Efficiency ratings based on the American Society of Heating, Refrigerating and Air Conditioning Engineers Standard 52.2-1999.
  • Page 2: Ordering Information

    If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care...
  • Page 3 Fig. 1. Installation dimensions in in. (mm) of air cleaner. Media Replacement: Replace the filter at least annually or when the built-in pressure sensors in the F200 door detect that airflow is impaired and the filter requires cleaning. This condition causes the indicator light BACK SIDE OF DOOR...
  • Page 4: Planning The Installation

    WHEN FIRST INSTALLED. PRESSURE DROP INCREASES AS FILTER BECOMES LOADED. REPLACE FILTER WHEN PRESSURE DROP REACHES 0.5 IN. WC. (0.1 kPa). M32859 Fig. 3. Capacity, Pressure Drop and Area of F200 Filter Media. PLANNING THE INSTALLATION M14786 Fig. 4. Highboy furnace, with side installation. Media air...
  • Page 5 F200 CHARGED-MEDIA AIR CLEANER M14789 M14789 M941A M941A Fig. 8. Counterflow furnace, with media air cleaner mounted horizontally in return duct or plenum just above Fig. 6. Highboy furnace, with closet installation. Media air furnace. cleaner is mounted vertically on furnace between furnace and louvered return air opening in closet door.
  • Page 6: Turning Vanes

    F200 CHARGED-MEDIA AIR CLEANER 2.Use no more than 20 degrees (about 4 in. per running ft. (100 mm per 300 linear mm)) of expansion on each side of a transition fitting. Turning Vanes If the media air cleaner is installed next to an elbow or angle fitting, add turning vanes inside the angle to distribute airflow more evenly across the face of the media.
  • Page 7 The media air cleaner cannot The AIRWATCH® Indicator provides a signal when the F200 remove dirt that has settled in the blower compartment and filter needs replacing. When the filter begins restricting airflow distribution ducts.
  • Page 8: Select Location

    • Original furnace filter has been removed and blower four arrows come on (about five seconds). compartment is cleaned. 3. Push the red reset button on the F200 door within two minutes. 4. Observe the indicator arrows on the RF AIRWATCH®...
  • Page 9 F200 CHARGED-MEDIA AIR CLEANER Table 1. AIRWATCH® Indicator LCD Description. AIRWATCH® Indicator Condition Meaning/Action No indicator on. AIRWATCH® has no power; replace battery in AIRWATCH® On/Battery indicator on continuously. AIRWATCH® is functioning normally. On/Battery indicator flashing. Flashing two seconds on, six seconds off: Replace battery in the RF door.
  • Page 10 F200 CHARGED-MEDIA AIR CLEANER Table 2. F200E Parts List. Callout F200E1003 F200E1029 F200E1011 F200E1037 Description 16 x 20 in. 16 x 25 in. 20 x 20 in. 20 x 25 in. Replacement filter FC200E1003 FC200E1029 FC200E1011 FC200E1037 Door with RF Transmitter...
  • Page 11: Filtre À Air À Auto-Ionisation F200

    • Le signal de remplacement du filtre est transmis à un indicateur mural AIRWATCH • L'indicateur AIRWATCH à radiofréquences est inclus. APPLICATION Le filtre à air à auto-ionisation F200 retient une importante quantité de particules contenues dans l'air qui le traverse. Contents Application/Caractéristiques ..........Fiche technique/Pour commander ........
  • Page 12: Fiche Technique

    Minneapolis, Minnesota 55422-4386 Au Canada : Honeywell Limited-Honeywell Limitée, 35 Dynamic Drive, Toronto (Ontario) M1V 4Z9. Points de vente et de service dans toutes les grandes villes du monde. Usines en Allemagne, en Australie, au Canada, en Espagne, aux États-Unis, en Finlande, en France, au Japon, au Mexique, aux Pays-Bas, au Royaume-Uni et à...
  • Page 13: Remplacement Du Médium Filtrant

    INTƒRIEUR DE LA PORTE l'écoulement d'air a diminué et qu'il faut nettoyer le filtre. Dans un tel cas, le voyant situé sur la porte du F200 s'allume et clignote, et le transmetteur envoie un signal à l'indicateur mural à radiofréquences, indiquant ainsi à...
  • Page 14: Planification De L'installation

    FILTRE À AIR À AUTO-IONISATION F200 Choisir la position d'installation du 406 x 635 mm (16 x 25 po) filtre 508 x 508 mm (20 x 20 po) Le filtre à air peut être installé dans n'importe quelle position, mais les flèches figurant sur la cartouche doivent pointer dans le même sens que celui de l'écoulement de l'air.
  • Page 15 FILTRE À AIR À AUTO-IONISATION F200 M14789 M14789 Fig. 8. Appareil de ventilation centrale. Filtre à air installé M941A à l'horizontale dans une gaine de reprise centrale. Fig. 6. Appareil de chauffage à caissons juxtaposés. Filtre à air installé à l'horizontale dans le plénum d'air repris juste au-dessus de l'appareil de chauffage, face au plénum...
  • Page 16: Déflecteurs

    FILTRE À AIR À AUTO-IONISATION F200 Déflecteurs Si le filtre à air est installé près d'un coude (raccord à angle), installer les déflecteurs à l'intérieur du coude pour assurer une distribution d'air plus uniforme à la surface du filtre. Voir la Fig. 13.
  • Page 17 émet un signal lorsqu'il faut peuvent s'avérer nécessaires dans le cas d'un autre système. remplacer le filtre du F200. Lorsque le filtre devient trop encrassé et qu'il diminue l'écoulement de l'air, des capteurs de Passer en revue le plan de pression intégrés au F200 transmettent un signal radio à...
  • Page 18: Choisir Un Emplacement

    2. Observer la flèche qui indique quelles minuteries sont en choisi. Utiliser du ruban adhésif pour le maintenir en service. place. b. Au F200, appuyer sur le bouton de réarmement situé Pour mettre une minuterie en service : sur la porte. 1. Appuyer sur le bouton de l'indicateur AIRWATCH c.
  • Page 19 L'indicateur a reçu un signal du transmetteur signifiant soit que la chute de pression est trop élevée ou que la période de 12 mois entre deux remplacement de filtre est écoulée. Remplacer le filtre et appuyer sur le bouton de réarmement situé sur la porte du F200. Flèche du système UV ou flèche Il faut remplacer les lampes du systèmes UV ou le tampon de l'humidificateur.
  • Page 20 FILTRE À AIR À AUTO-IONISATION F200 Tableau 2. Liste des pièces du F200. F200E1003 F200E1029 F200E1011 F200E1037 Description 16 x 20 en po 16 x 25 en po 20 x 20 en po 20 x 25 en po Filtre de recharge...

Table des Matières