GB
Mounting
RMU 40 cannot be installed directly against a wall be-
cause the connection terminal protrudes from the reverse.
Install RMU 40 either in a spare apparatus box or on the
plastic spacer supplied.
If you want to use the room temperature sensor in
RMU 40 the position of the room unit is important. See
section "Room sensor".
1.
Open RMU 40 by inserting a screwdriver in one of
the 4 mm wide gaps in the edge. Press the screw-
driver straight in to open the clips. Repeat for the
other three clips.
2.
Without plastic spacer: Place the rear panel in front
of the apparatus box and screw to the wall.
With plastic spacer: Screw the plastic spacer into the
wall. Then screw the the rear panel into the plastic
spacer with the two screws supplied.
3.
Connect according to section "Electrical connection".
14
4.
Angle the front panel approx. 30 ° and secure the
two clips on one side. Then close the unit and secure
the two clips on the other side.