3.4.11 Set siren prompt off when arm/disarm
Format:
[009] + [**]
3.4.12 Set the user ID of main panel
Format:
[xxxx(4 digits ID)] + [*] + [#] + [0]
Description: Set user ID of main panel when connected to the Alarm center.
Example:
[1212] + [*#0]
Remark: Set the user ID to be 1212
3.4.13 Set alarm center phone number
Format:
[xxxxxxxx(center numbers)] + [*] + [#] + [8(9)]
Description: User could set up 2 alarm center phone numbers when the main
panel connected to the alarm center. If the alarm is activated, the main panel
would dial the two alarm center number at first in turn for three times, then dial
the others 6 groups of users'phone numbers.
Example:
[Record] + [55558888] + [*] + [#] + [9] + [Record]
Remark:
Set the 2nd alarm center number to "55558888".
3.5 Coding detectors with main unit
3.5.1 Enter coding mode:
Keep on pressing down "Code" key at side of main panel for about 4s to 5s until
hear one "Di" beep, then release the key, the system enter into wireless detectors
coding mode, and the "out" indicator blinks.
3.5.2 Exit coding mode
Press "Code" key again, the main panel ends coding process with two "Di...Di"
beeps. It exits coding status automatically if no any keypressing in 30s.
3.5.3 Coding process of wireless detectors
All wireless detectors had been registered (coded) to the main panel from the
factory. User can re-code them according to actual needs, the below is the coding
process.
1)
Choose Zone No.
In coding mode, please input the defense zone number(1 to 8) of
detectors you would like to register.
For example, you would like to code the wireless PIR sensor in defense
zone 2, please press key "2", and the zone 2 indicator blinks.
2)
Press the " out " key, the detectors would be coded into Arm out mode,
the " out " indicator flash.
Press the"Home" key, the detectors would be coded into Arm at home
mode, the "Home" indicator flash.
2)
Trigger the detectors
Trigger the detectors one by one by deparating the door contact sensor,
walking around in the PIR detection area, pressing the key button of
Code the detectors in Arm Out or Arm Home mode
-- - 33 --